Ultrasonic Image Characteristics of Palatine Tonsils in Healthy Children and Analysis of Factors Influencing Image Quality

open access: yesJournal of Clinical Ultrasound, Volume 53, Issue 3, Page 436-444, March/April 2025.
The ultrasound detection rate of the palatine tonsils in children was good. There are characteristic ultrasonic image manifestations. Tonsil ultrasound image quality is affected by individual and local factors. ABSTRACT Objective To explore the ultrasonic image characteristics of palatine tonsils in healthy children and the factors affecting image ...
Ying Cao   +5 more
wiley   +1 more source

Study of Risk Factors and Image Findings of Isolated Abdominal Incidentally Detected Aortic Dissection

open access: yesJournal of Clinical Ultrasound, Volume 53, Issue 3, Page 429-435, March/April 2025.
We detect the risk factors and image characteristics of incidentally detected IAAD. Independent risk factors of IAAD included fatty liver and smoking. In the ultrasound findings of IAAD, an intimal flap was frequently observed. In the CT scan, displacement of intimal calcifications was frequently observed. For suspected IAAD, the abdominal aorta should
Hiromasa Tsubouchi   +15 more
wiley   +1 more source

Comparison of the SMI Technique and CEUS for the Assessment of Microvasculature in Leiomyosarcoma and Its Clinical Value for Application

open access: yesJournal of Clinical Ultrasound, EarlyView.
SMI and CEUS can clearly reflect the microvascular situation in fibroids and effectively guide the clinical treatment of patients with uterine fibroids, but the effect of SMI is better than that of CEUS in guiding the treatment of patients, which can provide a reference for the selection of clinical treatment programs.
Qiufeng Li, Junbin Du
wiley   +1 more source

Developing a New Method for MRI Triggering Using Doppler Ultrasound

open access: yes, 2019
Purpose: Magnetic Resonance Imaging (MRI) is a medical imaging technique used in radiology to produce high quality images of the anatomy and the physiological processes of the body. Cardiac gating is a triggering system used for the MRI scanner to synchronize the MRI scanner with the cardiac cycle of the patient while imaging.
openaire   +1 more source

High‐Frequency Ultrasonographic Characterization of Subcutaneous Glomus Tumors

open access: yesJournal of Clinical Ultrasound, EarlyView.
Color Doppler image reveals intralesional hypervascularity. ABSTRACT Objective To evaluate the clinical manifestations and ultrasonographic characteristics of glomus tumors under the nails and other subcutaneous soft tissues. Methods A retrospective analysis was performed on 45 patients with pathologically confirmed glomus tumors who underwent ...
Mingyu Bai, Nan Wang, Jie Jiang
wiley   +1 more source

The Application Value of Transvaginal Three‐Dimensional Ultrasonography in the Diagnosis of Adenomyosis of the Uterus

open access: yesJournal of Clinical Ultrasound, EarlyView.
In this study, 3D‐TVS measurements of the uterine junction zone (JZ) in 120 patients showed that a JZmax threshold of ≥ 0.45 cm yielded 77% sensitivity and 89% specificity for adenomyosis diagnosis. Notably, JZ thickness varies minimally with age, demonstrating its stability and excellent diagnostic performance.
Mengyu Li   +3 more
wiley   +1 more source