Results 61 to 70 of about 123,219 (258)

Ultrasound Guidance for Botulinum Neurotoxin Chemodenervation Procedures

open access: yesToxins, 2017
Injections of botulinum neurotoxins (BoNTs) are prescribed by clinicians for a variety of disorders that cause over-activity of muscles; glands; pain and other structures.
Katharine E. Alter, Barbara I. Karp
doaj   +1 more source

Microstructure, Thermal Transport, and Dry‐Sliding Tribology of Powder‐Metallurgy Al7075 Composites Reinforced With Sol–Gel‐Derived ZnO–rGO Hybrid Nanoparticles

open access: yesAdvanced Engineering Materials, EarlyView.
Sol–gel‐derived ZnO–rGO hybrid nanoparticles enable Al7075 powder‐metallurgy composites to achieve concurrent gains in hardness and thermal conductivity while markedly lowering friction and wear. The hybrid architecture couples ZnO‐based load support with rGO‐assisted lamellar sliding and heat spreading, revealing a promising route toward lightweight ...
Bunyamin Aksakal   +3 more
wiley   +1 more source

Biomass Native Structure Into Functional Carbon‐Based Catalysts for Fenton‐Like Reactions

open access: yesAdvanced Functional Materials, EarlyView.
This study indicates that eight biomasses with 2D flaky and 1D acicular structures influence surface O types, morphology, defects, N doping, sp2 C, and Co nanoparticles loading in three series of carbon, N‐doped carbon, and cobalt/graphitic carbon. This work identifies how these structural factors impact catalytic pathways, enhancing selective electron
Wenjie Tian   +7 more
wiley   +1 more source

Transfer Printing and Reconfiguration of Soft Electronics Using Digital Microfluidics and Laser Machining

open access: yesAdvanced Functional Materials, EarlyView.
This paper presents a digital microfluidics‐based technique for transferring and reconfiguring soft nanomembranes. Laser‐machined nanothin membranes are picked up, transported, and aligned via tailored surface tension and the actuation of water droplets, enabling the development of flexible electronics, the integration of functional materials on 3D ...
Quang Anh Nguyen   +15 more
wiley   +1 more source

Exciton Binding Energy of Phosphorescent Emitter Molecules in Organic Light‐Emitting Diodes

open access: yesAdvanced Functional Materials, EarlyView.
Energy level alignment is key to efficient OLED design, yet determining LUMO energies remains challenging. A methodology based on field‐induced dissociation and kinetic Monte Carlo simulations is presented to extract LUMO energies of iridium‐based phosphorescent emitters from their exciton binding energy.
Hiroki Tomita   +6 more
wiley   +1 more source

Intralymphatic Immunotherapy with Ultrasound Guidance Seems to Be Associated with Improved Clinical Effect in Canine Atopic Dermatitis—A Retrospective Study of 109 Cases

open access: yesAnimals
Background: Intralymphatic immunotherapy (ILIT) has been used successfully in both human and veterinary medicine as a safe and effective treatment for allergic diseases.
Nina Maria Fischer   +3 more
doaj   +1 more source

Near‐Infrared Light‐Driven Zn/Au Janus Micromotors for Multiplex SERS Detection of Anticancer Drugs

open access: yesAdvanced Functional Materials, EarlyView.
Zn/Au Janus micromotors, propelled by thermophoretic effects under NIR light, function as active SERS platforms for single and multiplex detection of anticancer drugs. Their dynamic motion enhances analyte exchange at the Au interface, reducing saturation and competitive adsorption, thereby improving sensitivity and extending the linear detection range.
Tijana Maric   +8 more
wiley   +1 more source

Guidance for clinical practice using emergency and point‐of‐care ultrasonography

open access: yesAcute Medicine & Surgery
Owing to the miniaturization of diagnostic ultrasound scanners and their spread of their bedside use, ultrasonography has been actively utilized in emergency situations.
Toru Kameda   +12 more
doaj   +1 more source

Cost-effectiveness-analysis of ultrasound guidance for central venous catheterization compared with landmark method: a decision-analytic model

open access: yesBMC Anesthesiology, 2019
Background Ultrasound guidance for central venous catheterization is a commonly used alternative to the conventional landmark method. Because from the German perspective, the cost-effectiveness of ultrasound guidance is unclear, this study examined the ...
Yana Seleznova   +4 more
doaj   +1 more source

Mechanoluminescent HOF Nanotransducers Enabled Sono‐Optogenetics in Parkinsonian Rats

open access: yesAdvanced Functional Materials, EarlyView.
We present a mechanoluminescent system utilizing porous hydrogen‐bonded organic frameworks (HOFs) as a toolkit for focused ultrasound‐triggered, non‐invasive light delivery to the deep brain in rats. This approach enables the specific activation of PV‐GPe neurons in dopamine‐depleted Parkinson's disease rat models, resulting in a comparable alleviation
Wenliang Wang   +18 more
wiley   +1 more source

Home - About - Disclaimer - Privacy