Behaviour analysis of H‐bridge high‐voltage capacitor banks fault on 230‐kV substation using discrete wavelet transform [PDF]
The protection of traditional high‐voltage capacitor banks relies on an unbalance relay which operates when an internal fuse is blown. However, the unbalance relay cannot indicate the cause of the fault.
Pathomthat Chiradeja +3 more
doaj +2 more sources
Research on Interference Mechanism of 25 Hz Phase Sensitive Track Equipment from Unbalanced Current [PDF]
In a 25-Hz phase-sensitive track circuit, traction backflow is unevenly distributed in the two rails, resulting in interference caused by the 50 Hz unbalanced current, which leads to misoperation of relays and other equipment in the circuit.
Lei Wang +6 more
doaj +2 more sources
Replacement of several single function generator protection relay at Badak LNG [PDF]
Badak LNG is a company that operates the largest LNG Plant in Indonesia with maximum production capacity of 22.5 MTPA. The company operates twelve (12) steam turbine generators and one gas turbine generator and one diesel engine generator to supply ...
Perdana Iqbal Nusya
doaj +3 more sources
Intelligent Over-vibration Protection Modeling & Simulation For Three Phase Induction Motor [PDF]
This paper presents an intelligent over-vibration simulation and protection preference for three phase medium and high power induction motor. Three phase induction motor is widely used in industry because they are rugged, reliable and economical ...
Ayman Eissa
doaj +3 more sources
Improved Transformer Differential Protection by Adaptive Pickup Setting during Momentary Over-Fluxing Condition [PDF]
The differential relaying scheme is universally adopted as the main protection for power transformer. In certain situations, like temporary over-fluxing, this differential protection may malfunction.
Maulik Raichura +2 more
doaj +3 more sources
Taking into account the influence of asymmetric traction load on the choice of the response parameters of blocking during oscillations of distance protection [PDF]
Introduction. The paper considers the problem of the influence of asymmetric traction load (ATL) on the functioning of relay protection, in particular, blocking during swings (BD) of distance protection (DP).Goal.
V. I. Nagay +4 more
doaj +3 more sources
Dynamic Analyses of the Hydro-Turbine Generator Shafting System Considering the Hydraulic Instability [PDF]
Hydraulic instability is a complex factor causing the vibration of hydro-turbine generator shafting system (HGSS), and the mechanism is the uneven distribution of flow along the circumference.
Keyun Zhuang +4 more
doaj +2 more sources
In the oil and gas industry, continuous processes such as oil and gas refining play a great role and are sensitive to many external factors. Such processes require special procedures for stopping and restarting. In order to maintain a sustainable process,
V. V. Dmitrieva, A. B. Khammatov
doaj +1 more source
Capacitor faults are a common issue in modern-day power systems. Such systems employ a traditional mechanism that solely relies on unbalanced relays as an indicator of faults in capacitor banks; however, in the case of a relay trip, operators may find it
Praikanok Lertwanitrot +1 more
doaj +1 more source
The protection of conventional high voltage capacitor banks relies on an unbalance relay. However, investigating the faults requires time and human resources.
Pathomthat Chiradeja +1 more
doaj +1 more source