Results 31 to 40 of about 894,209 (150)
Flexible Power Control of PV Grid-connected Quasi-Z Source Inverter under Unbalanced Faults
Under unbalanced grid voltages, the currents injected into the grid become non-sinusoidal and unbalanced. The unbalanced grid current and voltage may lead to double-frequency oscillations in the active and reactive power.
Zhao, Zhengyu +3 more
core +1 more source
Power Quality Improvement for Grid Connected Inverters under Distorted and Unbalanced Grids
A power quality improvement scheme for grid connected inverters, even in the presence of the disturbances in grid voltages due to harmonic distortions and three-phase imbalance, is presented for distributed generation (DG) power systems. The control objective is to force the inverter currents to follow their references with robustness even under ...
Hyun-Sou Kim +2 more
openaire +2 more sources
Model predictive control strategy for NPC grid‐connected inverters in unbalanced grids
A model predictive control (MPC) strategy for a three‐phase three‐level neutral point clamped (NPC) grid‐connected inverter is discussed. Conventional two‐level inverters are effective when a symmetric fault occurs. But when a three‐phase unbalanced fault occurs, they will generate errors and introduce delay in the power system because of the complex ...
Tao Jin +3 more
openaire +1 more source
Balancing the electricity smart grid without unbalancing the family [PDF]
Løgstrup, Louise Buch +3 more
openaire +2 more sources
In this paper, a linearized direct power control strategy for grid-connected inverters under distorted unbalanced grid voltage is proposed. The grid-connected inverters usually suffer from distorted unbalanced grid condition, which causes output active ...
Yi-Hung Liao +2 more
core +1 more source
The grid-voltage unbalance can result in a double-frequency component in the output power of a three-phase grid-connected converter, which significantly degrades the system performance.
Fen Tang +9 more
core +1 more source
Three-phase grid-tied inverters are usually designed to operate in symmetric grid impedance. In actual operations, due to the imbalanced loads, three-phase systems with significant single-phase loads, imbalanced power line impedance or the imbalanced ...
Liu, Jiahao +3 more
core
The performance of Volt/VAr optimization has been significantly improved due to the integration of measurement data obtained from the advanced metering infrastructure of a smart grid.
Taheri, Javid, +4 more
core +1 more source
Planning of energy storage systems in unbalanced microgrids
This paper proposes a planning technique aimed at optimally sizing and locating distributed storage devices in an unbalanced low voltage microgrid. The planning procedure is formulated in terms of a mixed, non linear, constrained optimization problem ...
Russo, A. +7 more
core +1 more source
Predictive current control(PCC) scheme of doubly-fed induction generator(DFIG) system under unbalanced power grid is obtained by discretizing the mathematical model of rotor side converter(RSC) and grid side converter(GSC) of DFIG in the two-phase ...
HU Youqun +5 more
core +1 more source

