Results 251 to 260 of about 74,909 (294)
Some of the next articles are maybe not open access.
IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society, 2017
In this paper, an improved grid voltage modulated control (GVM) with power compensation is proposed for grid-connected voltage inverters when the grid voltage is unbalanced. The objective of the proposed control is to remove the power ripple and to improve current quality.
Li, Mingshen +3 more
openaire +2 more sources
In this paper, an improved grid voltage modulated control (GVM) with power compensation is proposed for grid-connected voltage inverters when the grid voltage is unbalanced. The objective of the proposed control is to remove the power ripple and to improve current quality.
Li, Mingshen +3 more
openaire +2 more sources
Control of Grid Connected MMC Under Balanced & Unbalanced Grid Conditions
2018 2nd International Conference on Trends in Electronics and Informatics (ICOEI), 2018With the advancement in power electronic systems the need for power electronic converters with increased reliability and efficiency of the conversion processes in medium and high power applications is ever growing. These requirements are ably fulfilled by the Modular Multilevel Converters (MMCs).
Mitali H Patel, Mukesh M Bhesaniya
openaire +1 more source
Circulating Current Suppression for MMC-HVDC under Unbalanced Grid Conditions
IEEE Transactions on Industry Applications, 2016Modular multilevel converter (MMC) is believed the most competitive solution for high-voltage direct current (HVDC) transmission using voltage source converters. Circulating current suppressing strategies based on proportional resonant (PR) controllers are widely used in MMC. This kind of strategies can effectively eliminate all the circulating current
null Jinyu Wang +3 more
openaire +1 more source
Small-Signal Stability of MMC Grid-Tied System Under Two Typical Unbalanced Grid Conditions
IEEE Transactions on Industry Applications, 2021The AC transmission network of Modular Multilevel Converters (MMC) usually adapts the overhead line, so the single-phase grounding faults of the AC side are rather general. At this time, the protection system will cut off the fault line for the first time, so there are two unbalance grid conditions (UGCs), i.e.
Jianhang Zhu +4 more
openaire +1 more source
Analysis of wind driven grid connected induction generators under unbalanced grid conditions
IEEE Transactions on Energy Conversion, 1994A wind driven induction generator feeding power to the grid has been analyzed under the abnormal condition of unbalanced grid voltages. Using the symmetrical component and double revolving field theory, appropriate equivalent circuits and model equations have been derived for the generating mode with suitable realistic modifications.
A.H. Ghorashi +3 more
openaire +1 more source
Control strategy for inverter in a micro-grid under unbalanced grid condition
2016 IEEE Conference on Technologies for Sustainability (SusTech), 2016Micro-grid is gaining momentum as it addresses grave concerns like climate change and energy security. This paper presents power flow control algorithm for voltage source inverter used in a micro-grid under unbalanced grid conditions. Energy Storage and local energy source are the key components of the micro-grid that is required to help stabilize grid.
L. Ashok Kumar, Sheeba Babu
openaire +1 more source
Voltage source converter control under unbalanced grid voltage conditions
2017 XXVI International Conference on Information, Communication and Automation Technologies (ICAT), 2017This paper proposes a novel control method for voltage source converter (VSC) connected to grid under unbalanced voltage conditions. The method is based on utilizing the full control capabilities of the switching converter. The proposed method makes the voltage source inverter (VSI) supply the voltages according to the requirements of the load and/or ...
Akhtar Rasool +2 more
openaire +1 more source
Performance of BDFIG During Balanced and Unbalanced Grid Conditions
2020 IEEE First International Conference on Smart Technologies for Power, Energy and Control (STPEC), 2020In this paper direct torque control (DTC) based brushless doubly fed induction generator (BDFIG) with space vector modulation (SVM) and a PI controller is proposed. Effective operation of DTC of BDFIG by improving steady state operation is proposed by minimizing flux and torque pulsations.
Upadhyayula J.A. Panini Sarma +1 more
openaire +1 more source
Small-Signal Model and Dynamics of MMC-HVDC Grid Under Unbalanced Grid Conditions
IEEE Transactions on Power Delivery, 2021Small-signal models (SSM) of modular multilevel converter (MMC) based HVDC grid under unbalanced grid conditions in recent literatures do not consider interactions between MMC and dc network. Therefore, it is necessary to correctly model the double-fundamental-frequency zero-sequence circulating currents (DFF-ZSCC) existing under unbalanced grid ...
Quanrui Hao +4 more
openaire +1 more source
Robust Backstepping Control of Synchronverters under Unbalanced Grid Condition
2019 IEEE Power and Energy Conference at Illinois (PECI), 2019Virtual Synchronous Generators, known as synchronverters, are inherently nonlinear systems and maintaining their consistent operation under faulty and distorted grid requires a nonlinear control design. This paper presents backstepping as an adaptive stabilizing technique which enables full power injection to the grid under unbalanced and weak ...
Sara Yazdani, Mehdi Ferdowsi