Results 121 to 130 of about 13,919 (263)

Inter‐Shot Motion Correction of Segmented 3D‐GRASE ASL Perfusion Imaging With Self‐Navigation and CAIPI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1557-1571, October 2026.
ABSTRACT Purpose Segmented 3D Gradient and Spin Echo (GRASE) is commonly used in Arterial Spin Labeling (ASL) perfusion imaging. However, it is vulnerable to inter‐shot motion, leading to subtraction errors that cannot be corrected. We developed a retrospective self‐navigated inter‐shot motion correction method for segmented 3D‐GRASE ASL imaging with ...
Minhao Hu   +5 more
wiley   +1 more source

Collaborative Reconstruction of PROPELLER‐EPI Data Using POCSMUSE (CORPUSE) for High‐Fidelity Diffusion MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1929-1946, October 2026.
ABSTRACT Purpose To develop a reconstruction framework for DW‐PROPELLER‐EPI that improves image quality and SNR efficiency under per‐blade acceleration while minimizing EPI‐related artifacts, enabling high‐resolution diffusion‐tensor imaging (DTI) with fewer blades.
Hailin Xiong   +7 more
wiley   +1 more source

BART Streams: Real‐Time Reconstruction Using a Modular Framework for Pipeline Processing

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1534-1544, October 2026.
ABSTRACT Purpose To create modular solutions for interactive real‐time MRI using reconstruction algorithms implemented in BART. Methods A new protocol for streaming of multidimensional arrays is presented and integrated into BART. The new functionality is demonstrated using examples for cardiac interactive real‐time MRI based on radial FLASH, where ...
Philip Schaten   +4 more
wiley   +1 more source

Methods for Uncertainty Quantification in Dictionary Matching to Advance Reliability of Quantitative MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1956-1971, October 2026.
ABSTRACT Aims Purpose: Dictionary matching is a standard tool in quantitative MRI (qMRI), but typically lacks uncertainty quantification (UQ). This is critical when advanced reconstructions (e.g., compressed sensing, deep learning) introduce complex‐valued, spatially varying, and temporally correlated noise that violates standard assumptions of ...
Brian Toner   +7 more
wiley   +1 more source

Simultaneous T2, T2*, and R2′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE‐EPI MRI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1872-1892, October 2026.
ABSTRACT Purpose To demonstrate the synergy of undersampled radial 2in1‐RARE‐EPI acquisition and nonlinear model‐based reconstruction for accelerated and simultaneous T2, T2*, and R2′ mapping in brains of patients with multiple sclerosis (MS). Methods 2in1‐RARE‐EPI combines a RARE module with an EPI module to capture T2 and T2* information.
Jose Raul Velasquez Vides   +16 more
wiley   +1 more source

CLEANSE – Cluster-based Undersampling Method

open access: yesProcedia Computer Science, 2023
Malgorzata Bach   +3 more
openaire   +1 more source

Zero‐Shot Self‐Supervised Learning of Single Breath‐Hold Magnetic Resonance Cholangiopancreatography (MRCP) Reconstruction

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1666-1681, October 2026.
ABSTRACT Purpose To investigate the feasibility of zero‐shot self‐supervised learning reconstruction for reducing breath‐hold times in magnetic resonance cholangiopancreatography (MRCP). Methods Breath‐hold MRCP was acquired from 11 healthy volunteers on 3T scanners using an incoherent k‐space sampling pattern, leading to a 14‐s acquisition time and an
Jinho Kim   +2 more
wiley   +1 more source

Laterally Oscillating Trajectory for Undersampling Slices: LOTUS

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 4, Page 1682-1695, October 2026.
ABSTRACT Purpose While spiral sampling offers SNR advantages for diffusion MRI, its acceleration with simultaneous multislice remains relatively unexplored. This study introduces Laterally Oscillating Trajectory for Undersampling Slices (LOTUS), which is a 3D spiral‐like k‐space trajectory that aims to minimize g‐factor via controlled incoherent ...
Mayuri Sothynathan   +2 more
wiley   +1 more source

Feasibility of longitudinal relaxation rate mapping with non-Cartesian sampling and compressed sensing on a 1.5 T magnetic resonance linear accelerator. [PDF]

open access: yesPhys Imaging Radiat Oncol
McCullum L   +10 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy