Results 141 to 150 of about 656 (183)
Some of the next articles are maybe not open access.
Failure of Unreinforced Masonry Under Compression
Structures Congress 2013, 2013The contribution presents novel observations on unreinforced masonry made of solid clay brick units and surrounding mortar joints. Focus is the brittle-ductile interaction of the two constituents in form of the so-called masonry prism test under axial compression.
Kaspar Willam +3 more
openaire +1 more source
Acoustic tomography for evaluation of unreinforced masonry
Construction and Building Materials, 1997A joint U.S./Italian effort is investigating the effectiveness of grout injection for repair of damaged or deteriorated masonry structures. A nondestructive acoustic tomographic imaging technique has been used throughout the program to determine the effectiveness of the repair processes.
M Schuller, M Berra, R Atkinson, L Binda
openaire +1 more source
Seismic Assessment of Unreinforced Masonry Buildings
Applied Mechanics and Materials, 2016The first case study used in this work is an existing seven-storey unreinforced masonry building (representing a typical residential building located in the district of L ́Example in Barcelona). The accuracy of the non-linear static procedures was evaluated by comparison with non-linear dynamic analyses for seven ground motion records and different ...
Jorge Arturo Avila-Haro +2 more
openaire +1 more source
Seismic Assessment of Unreinforced Masonry Walls
2007This thesis focuses on the seismic performance of unreinforced masonry wall perforated with a door opening representing typical URM walls of many aged masonry buildings in Indonesia. To obtain a test result that will be able to represent the local conditions, the experiments have been conducted in the Research Institute for Human Settlements (RIHS ...
openaire +2 more sources
Design Analysis of Unreinforced Masonry Structures
1998Three analytical problems arise in the design of masonry structures, which relate to (1) the distribution of vertical loads among the various walls in the building, (2) the determination of eccentricity of loading on walls, and (3) the distribution of lateral loads on the walls.
openaire +1 more source
Seismic Rehabilitation of Unreinforced Masonry Walls
SP-188: 4th Intl Symposium - Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures, 1999The U.S. Army Construction Engineering Research Laboratory, in partnership with the Composite Institute of the Society of Plastics Industry, Inc. and in support of the Army's facility seismic rehabilitation efforts, is investigating the applicability of fiber reinforced polymer (FRP) composite materials systems to strengthen unreinforced masonry (URM ...
openaire +1 more source
Earthquakes and unreinforced-masonry buildings
1993Aussi disponible en francais: Séismes et bâtiments de maçonnerie non ...
openaire +1 more source
8 Unreinforced Masonry Buildings
Earthquake Spectra, 1996Peter Somers +6 more
openaire +1 more source
Statistical assessment of tensile and shear properties of unreinforced clay brick masonry
Construction and Building Materials, 2023Mark G Stewart +2 more
exaly

