Results 81 to 90 of about 7,786 (216)

Shake Table Response of Unreinforced Masonry and Reinforced Concrete Elements of Special Moment Resisting Frame

open access: yesAdvances in Civil Engineering, 2019
Half-scaled reinforced concrete frame of two storeys and two bays with unreinforced masonry (URM) infill walls was subjected to base excitation on a shake table for seismic performance evaluation.
Syed Azmat Ali Shah   +5 more
doaj   +1 more source

Seismic response analysis of concrete block masonry buildings: an experimental study using shaking table [PDF]

open access: yes, 2012
The combination of a series of structural and economic advantages like the high capacity to resist compressive loads, the simple and easy method of construction, comfort properties and structural performance given for the new masonry structures makes the
Alves, Pedro   +5 more
core  

Seismic assessment and improvement of unreinforced stone masonry buildings

open access: yesBulletin of the New Zealand Society for Earthquake Engineering, 2016
Following the 2010/2011 Canterbury earthquakes considerable effort was applied to the task of developing industry guidance for the seismic assessment, repair and strengthening of unreinforced masonry buildings. The recently updated “Section 10” of NZSEE 2006 is one of the primary outputs from these efforts, in which a minor amount of information is ...
Marta Giaretton   +3 more
openaire   +1 more source

Damages of Masonry School Buildings on 2010 Karakocan - Elazig Earthquake [PDF]

open access: yes, 2013
Masonary school buildings were damaged very heavly or coolapsed in Karakocan-Elazig-Turkey earthquake with M=6.0 occurred on 08 March 2010 at 04:32 a.m. (local time) at eastern Turkey and caused the loss of life and heavy damages, as well.
I. Turkmen, N. Cetinkaya
core  

A correlation between damage and intensity on old masonry churches in Colima, Mexico by the 2003 M7.5 earthquake [PDF]

open access: yes, 2014
Strong damage was observed in Colima Mexico on most of the cultural patrimony (mainly churches) after the 2003 M7.5 earthquake. In order to find a correlation between the observed damage on the historical buildings and the earthquake intensity, the ...
Orduña, Agustín, Preciado, Adolfo
core   +1 more source

Validation of masonry systems for in-plane lateral loading using truss reinforcement [PDF]

open access: yes, 2008
The paper presents and describes the main issues related to two building systems for modern masonry structures using truss reinforcement, currently under development at University of Minho, one based on lightweight concrete blocks and another based on ...
Freitas, Jeovan F.   +4 more
core  

Experimental and numerical study on the shear behavior of stone masonry walls strengthened with GFRP reinforced mortar coating and steel-cord reinforced repointing [PDF]

open access: yes, 2015
The research work herein presented is aimed at investigating the structural behavior of stone masonry walls reinforced through different strengthening techniques.
Amadio, Claudio   +2 more
core   +1 more source

Improvement in seismic performance of stone masonry using galvanized steel wire [PDF]

open access: yes, 2015
University of Technology, Sydney. Faculty of Engineering and Information Technology.This research is about using either freely available natural stone or rubble left behind earthquake disasters to build a seismic resistant house.
Pun, R
core  

Comprehensive Material Characterization and Seismic Performance Evaluation of a Traditional Masonry Residential Building with Reinforced Concrete Slabs

open access: yesBuildings
Reinforced concrete began replacing traditional masonry construction in the early 20th century, yet hybrid buildings combining unreinforced masonry (URM) walls with concrete slabs remain prevalent in Istanbul.
Basak Boduroglu Yazici, Oguz Uzdil
doaj   +1 more source

Experimental investigation on the seismic behaviour of new concrete block masonry buildings [PDF]

open access: yes, 2012
The present work deals with the experimental validation of a new structural solution for concrete block masonry buildings. Dynamic tests of two identical two-­story concrete block masonry models were performed on a shaking table in reduced scale 1:2 ...
Avila, Leonardo   +2 more
core  

Home - About - Disclaimer - Privacy