Results 31 to 40 of about 491,314 (222)
Alterations in myelin integrity are involved in many neurological disorders and demyelinating diseases, such as multiple sclerosis (MS). Although magnetic resonance imaging (MRI) is the gold standard method to diagnose and monitor MS patients, clinically
Caroline Guglielmetti +5 more
doaj +1 more source
ClC-2 Contributes to Hypotonicity-Induced Adrenal Aldosterone Secretion. [PDF]
ABSTRACT Aim The zona glomerulosa (ZG) of the adrenal cortex regulates blood pressure and electrolyte homeostasis through aldosterone production. In ZG cells, potassium and angiotensin II (Ang II) trigger calcium oscillations that drive aldosterone synthesis.
Volkert M +3 more
europepmc +2 more sources
Syntheses, crystal structures, and vibrational spectroscopic properties of MgCN2, SrCN2, and BaCN2 [PDF]
The alkaline-earth metal cyanamides MgCN* SrCN* and BaCN2 were prepared by the reaction of melamine with the metal nitrides (M&N2, Sr-jN, Ba3N2 ) at temperatures between 740 e C and 850 °C.
Berger, Ute, Schnick, Wolfgang
core +1 more source
Organización Institucional en el Sector Energético en el Uruguay y participantes en el mismo
La energía , su probable falta o escasez, precio y su importancia en la satisfacción de necesidades mínimas humanas, en el desarrollo y crecimiento de los países mediante la producción, aunque siempre ha sido un tema en estudio, ha cobrado en la ...
José A. Alem Deaces
doaj +2 more sources
A portable system for phasor measurment units (PMU) calibration in high-voltage substations
This paper presents the advances in the development of a portable PMU standard for online calibration of PMUs installed in high voltage substations. This system is intended to be connected in parallel with the PMU under test, without disconnecting it ...
Daniel Slomovitz +5 more
doaj +1 more source
Band-theoretical prediction of magnetic anisotropy in uranium monochalcogenides
Magnetic anisotropy of uranium monochalcogenides, US, USe and UTe, is studied by means of fully-relativistic spin-polarized band structure calculations within the local spin-density approximation.
B. Reihl +22 more
core +1 more source
Background To compare potential of ultrashort time-to-echo (UTE) T2* mapping and T2* values from T2*-weighted imaging for assessing lumbar intervertebral disc degeneration (IVDD),with Pfirrmann grading as a reference standard.
Li-Lan Wu +4 more
doaj +1 more source
Assessing cortical bone mechanical properties using collagen proton fraction from ultrashort echo time magnetization transfer (UTE-MT) MRI modeling. [PDF]
Cortical bone shows as a signal void when using conventional clinical magnetic resonance imaging (MRI). Ultrashort echo time MRI (UTE-MRI) can acquire high signal from cortical bone, thus enabling quantitative assessments.
Abbasi-Rad +61 more
core +2 more sources
Reconfigurable Magnetic Soft Microrobot for Acoustically Triggered Targeted Bacterial Sterilization
Reconfigurable magnetic soft microrobots integrate in situ‐grown piezoelectric zinc oxide nanorods that produce reactive oxygen species upon acoustic excitation. Combining magnetically guided transport with thermally induced planar reconfiguration, the microrobots achieve targeted delivery and enhanced bacterial sterilization through efficient on ...
Quan Gao +12 more
wiley +1 more source
Objectives To explore the feasibility of Ultra-short echo time (UTE) – MRI quantitative imaging in detecting early cartilage degeneration in vivo and underlying pathological and biochemical basis.
Xiaolian Su +5 more
doaj +1 more source

