Results 1 to 10 of about 448 (265)
DC interruption characteristic of vacuum circuit breaker
AbstractA high‐speed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes high‐frequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on the rate of change of the current (di/dt). As a fundamental research, we investigated the
Odaka, Hiromi +5 more
openaire +2 more sources
The generator circuit breaker is a special breaker located between a pumped storage machine and a step-up transformer. The first requirement for generator circuit breaker is to interrupt fault currents with delayed current zero, preventing the damage of ...
Weijie Wen +4 more
doaj +1 more source
INVESTIGATION OF MECHANICAL STRESSES IN THE DRIVE SHAFT OF MV VACUUM CIRCUIT BREAKER
Introduction. In the last 10-15 years a dominant position in the market of medium voltage circuit breakers, vacuum circuit breakers have taken in which as an actuator mono- or bistable actuators with permanent magnets are used.
E. I. Baida, B. V. Klymenko
doaj +1 more source
Among all circuit breaker faults, mechanical failures account for a considerable proportion, and online monitoring of their mechanical characteristics is of great practical significance.
Liting Weng +8 more
doaj +1 more source
Simulation study on modeling of vacuum arc characteristics and anode temperature rise in low-frequency vacuum interruption [PDF]
Low-frequency transmission technology has been widely used in medium- and long-distance electricity transmission scenarios such as offshore wind power transmission due to its advantages of low cost and strong ability to pool renewable energy.
Yanting Li +6 more
doaj +1 more source
Introduction. Currently, for switching medium voltage circuits, vacuum circuit breakers are widely used, which have good arcing properties and high breaking capacity.
E. I. Baida +4 more
doaj +1 more source
Research status and prospect of vacuum degree detection methods for vacuum circuit breaker
Research status of vacuum degree detection methods for vacuum circuit breaker was introduced including off-line detection methods such as observation method, power frequency withstand voltage method, pulsed magnetron discharge method and shield potential
WU Mengze +3 more
doaj +1 more source
Fault Interruption Scheme for HVDC System Using SiC-MESFET and VCB Based Hybrid Circuit Breaker
As high voltage DC power system is gaining popularity, power electronic switching devices are becoming increasingly advanced to overcome problems of timely fault isolation.
Waheed A. Khan +6 more
doaj +1 more source
The switching action of the main circuit breaker of the train will produce switching overvoltage. In order to suppress the switching overvoltage, the phase selection control of the circuit breaker is required.
Ruoyu Li +3 more
doaj +1 more source
Analysis of the Influence Factors of Post-Arc Dielectric Recovery on DC Vacuum Circuit Breaker
The DC vacuum circuit breaker adopts the artificial zero crossing commutation mode to interrupt the DC fault current, which is one of the control and protection methods that combines economy and reliability in DC system.
Xiaoming LIU +6 more
doaj

