Results 131 to 140 of about 665 (185)
Advancing Circular Composite Strategies by Vitrimer-Enabled Reuse of Unidirectional Laminates. [PDF]
Fuchs J, Schuhmann N, Alms J, Hopmann C.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Vacuum glazing: Current performance and future prospects
Vacuum, 2008The development of vacuum glazing is a significant advance in the area of low heat loss glazing systems with great potential to reduce building heating and when combined with solar control glazing, cooling loads. The basic concept of vacuum glazing is reviewed and the procedures and research undertaken in the development of both high-temperature and ...
Philip C Eames
exaly +2 more sources
Thermal outgassing of vacuum glazing
Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films, 1999Vacuum glazing consists of two sheets of glass separated by a narrow evacuated space. In this article we describe investigations of the causes of thermally induced degradation of vacuum glazing. It is shown that the rate of increase of pressure within the glazing during high temperature aging is mainly determined by the diffusion of water out of near ...
M. Lenzen, G. M. Turner, R. E. Collins
openaire +1 more source
Getters for vacuum insulated glazing
Vacuum, 2018Abstract The vacuum problem in sealed off chambers of VIGs type has been solved. The solution is based on two innovations. The first one is the usage of activationless getters in a form powders or granules of the composition Ca0.35Li0.45Mg0.20 instead of barium. The second one – the changed sequence of assembling the vacuum window at which the getter
K. Chuntonov +3 more
openaire +1 more source
Manufacture and cost of vacuum glazing
Fuel and Energy Abstracts, 1995The vacuum glazing project at the University of Sydney has progressed to the point where the main features of the vacuum glazing design are determined well. Over 500 glazings with areas up to one square meter have been formed. The stresses to which these glazings are or may be exposed have been studied extensively.
J.D. Garrison, R.E. Collins
openaire +1 more source
Photodesorption of gases in vacuum glazing
Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films, 2003When samples of vacuum glazing are exposed to sunlight, the pressure within these devices is observed to increase. The major gas species released have been identified using mass spectroscopic techniques, and are found to be carbon monoxide and carbon dioxide rather than water vapor as in thermally degraded vacuum glazing. Different measuring techniques,
N. Ng, R. E. Collins, L. So
openaire +1 more source
Evacuation and outgassing of vacuum glazing
Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films, 2000The evacuation and outgassing of vacuum glazing is studied by modeling and experimental methods. A two-dimensional finite difference method of modeling the pumpdown process is validated by comparison with a one dimensional, cylindrically symmetric finite difference method, and with measurements on experimental samples. In the absence of outgassing, the
N. Ng, R. E. Collins
openaire +1 more source
Thermal conductance measurement on vacuum glazing
International Journal of Heat and Mass Transfer, 2006zbMATH Open Web Interface contents unavailable due to conflicting licenses.
Ng, N., Collins, R. E., So, L.
openaire +1 more source
Vacuum glazing units and solar collectors
Applied Solar Energy, 2008Possible application of vacuum glazing (VG) units for transparent insulation of solar collectors (SC) to reduce their heat losses is considered. Taking into account the SC operating conditions, the heat insulating parameters of VG samples measuring 0.3 × 0.3 m2 and 0.5 × 0.5 m2 are experimentally studied and compared to those of double glazing (DG) of ...
S. N. Trushevskii, I. V. Mitina
openaire +1 more source
Thermal performance of an electrochromic vacuum glazing
Energy Conversion and Management, 2006Using a three-dimensional finite volume model, the thermal performance of an electrochromic vacuum glazing was simulated for insolation intensities between 0 and 1200 W m 2 . The electrochromic evacuated glazing simulated consisted of three glass panes 0.5 m by 0.5 m with a 0.12 mm wide evacuated space between two 4 mm thick panes supported by 0.32 mm ...
Yueping Fang, Philip C. Eames
openaire +1 more source

