Results 31 to 40 of about 120,245,468 (231)
Digital Cognitive Phenotyping for Differential Diagnosis and Monitoring in Neurological Conditions
ABSTRACT Objective To assess the utility, accessibility, and equivalence to supervised scales of online cognitive assessment in older individuals with cognitive impairment. Methods Patients with Alzheimer's disease (AD, n = 31), idiopathic normal pressure hydrocephalus (iNPH, n = 26), and traumatic brain injury (TBI, n = 23) completed online cognitive ...
Martina Del Giovane +10 more
wiley +1 more source
Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. [PDF]
BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is the recommended therapy for patients with severe aortic stenosis who are not suitable candidates for surgery. The outcomes beyond 1 year in such patients are not known.
Makkar, Raj R +26 more
core +1 more source
Background Transcatheter aortic valve replacement with supra‐annular transcatheter heart valves has been adopted in patients with degenerated surgical aortic valves.
Luis Augusto P. Dallan +11 more
doaj +1 more source
Bioprosthetic Aortic Valve Fracture During Valve-in-valve Transcatheter Aortic Valve Implantation [PDF]
The limited durability of surgical bioprostheses, combined with an ageing population, has led to an increasing demand for replacing degenerated bioprosthetic surgical heart valves, which is projected to increase. Valve-in-valve transcatheter aortic valve
John Phineas O’Donnell +1 more
core +1 more source
A female patient presented with severe, symptomatic aortic stenosis after distant surgical aortic valve replacement and subsequent transcatheter aortic valve implantation 6 years prior.
Brian J. Grondahl, DO, Gaurav Dhar, MD
doaj +1 more source
This article presents the design, modeling, and characterization of air‐pressure–actuated programmable vibroacoustic metamaterials (PVAMM). The study focuses on leveraging air pressure to dynamically tune resonance frequencies for effective noise attenuation.
William Kaal +2 more
wiley +1 more source
Sixteen year retrospective analysis of rheumatic and non-rheumatic heart disease patients undergoing valve procedures at Groote Schuur Hospital first incidence single aortic and mitral valve replacement [PDF]
Includes abstract.Includes bibliographical references.Rheumatic heart disease is still the most common cause of valvular heart lesions requiring replacement or repair procedures worldwide.
Ogunrombi, Akinwumi Babatunde
core +1 more source
Entropy‐Driven Design of Low‐Melting‐Point Alloys via Compositionally Complex Strategy
Conventional low‐melting‐point alloys (LMPAs) are limited by a narrow compositional space and inherent property trade‐offs. This review presents an entropy‐driven design strategy that overcomes these limitations, ushering in a new class of low‐melting‐point compositionally complex alloys (LMCCAs).
Yinghui Shang +6 more
wiley +1 more source
We shall discuss a patient who underwent a tricuspid valve‐in‐valve implantation for a failing bioprosthetic valve replacement. The procedure was complicated by detachment of the valve deployment apparatus which was removed in its entirety, using ...
Baldeep S. Sidhu +6 more
doaj +1 more source
Impact of Hydrogen Incorporation on Electronic and Magnetic Structure of X2CrNi18‐9 Stainless Steel
Hydrogen uptake in austenitic stainless steel alters both its electronic and magnetic structure. Seebeck measurements reveal hydrogen‐induced shifts in the electronic density of states, while neutron scattering uncovers nanoscale inhomogeneities that grow upon hydrogen incorporation, with the most pronounced effect observed in the PBF as‐built state ...
Torben Tappe +9 more
wiley +1 more source

