Results 131 to 140 of about 1,743,624 (256)

Pilot licensing after aortic valve surgery.

open access: yes, 2010
Background and aim of the study: Bicuspid aortic valve is the most common congenital heart malformation, and a high percentage of patients with this condition will develop complications over time.
Schnueriger, Hans   +5 more
core  

Clinical Outcomes of the Allegra Transcatheter System in Bioprosthetic Aortic Valve Failure: A Multicentre Valve‐in‐Valve Registry

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Introduction The prevalence of bioprosthetic aortic valve failure is increasing due to the broader use of bioprosthetic valves, both surgical and transcatheter, and an ageing population. Registry data indicate a higher risk of coronary obstruction and elevated gradients following valve‐in‐valve transcatheter aortic valve implantation (TAVI ...
Hilal Khan   +14 more
wiley   +1 more source

Diagnostic Accuracy and Feasibility of Quantitative Flow Ratio at Low Frame Rate Angiography: The Prospective Multicentre Australian AVALON Study

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated ...
Joseph M. O'Brien   +13 more
wiley   +1 more source

Use of Intracoronary Pressure Wire Assessment and Association With Outcomes: Insights From the British Cardiovascular Intervention Society National Database

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Despite recommendations in international guidelines, Intracoronary pressure wire assessment (PWA) utilization remains limited in clinical practice. This study aims to describe (i) trends of PWA during Percutaneous coronary interventional (PCI), (ii) factors that predict its application, and (iii) association with in‐hospital ...
Hussein Bashar   +3 more
wiley   +1 more source

Comparison Between the Acurate Neo and the Acurate Neo 2 Transcatheter Heart Valve System: Impact of Midframe Under‐Expansion

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius   +9 more
wiley   +1 more source

A Large Retrospective Study to Evaluate Utility of Zephyr Covered Stent in Transcatheter Closure of Sinus Venosus Defects

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Transcatheter closure (TCC) of sinus venosus defects (SVD) using balloon‐expandable covered stents is an emerging alternative to surgery. ZephyrCS (Sahajanand Laser Technologies, Gandhinagar, India) is available in long lengths to suit SVD closure.
Pramod Sagar   +3 more
wiley   +1 more source

A complex transcatheter mitral valve replacement and repair for the treatment of refractory severe mitral regurgitation

open access: yesHellenic Journal of Cardiology, 2016
Jose F. Condado   +7 more
doaj   +1 more source

Clinical Impact of Adherence to Fractional Flow Reserve Guidance in Acute Coronary Syndrome

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Fractional flow reserve (FFR) is established to guide revascularization in stable coronary disease and non‐culprit lesions in acute coronary syndromes (ACS). However, real‐world adherence to FFR guidance across the spectrum of ACS presentations, including ambiguous culprit scenarios, remains incompletely characterized.
Eun Ho Choo   +5 more
wiley   +1 more source

Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are
Seyed Hossein Aalaei‐Andabili   +2 more
wiley   +1 more source

Loss of hepatic SMLR1 causes hepatosteatosis and protects against atherosclerosis due to decreased hepatic VLDL secretion

open access: yesHepatology, EarlyView., 2022
The role of SMLR1 in lipid metabolism (high fat + cholesterol diet in mice) Abstract Background and Aims The assembly and secretion of VLDL from the liver, a pathway that affects hepatic and plasma lipids, remains incompletely understood. We set out to identify players in the VLDL biogenesis pathway by identifying genes that are co‐expressed with the ...
Willemien van Zwol   +22 more
wiley   +1 more source

Home - About - Disclaimer - Privacy