Unusual Spinal Epidural and Paraspinal Venous Engorgement Secondary to Hepatosplenic Schistosomiasis: A Rare Cause of Severe Low Back Pain. [PDF]
ABSTRACT Severe low back pain from spinal epidural and paraspinal venous engorgement secondary to hepatosplenic schistosomiasis is rare. MRI revealed dilated epidural veins and neural foraminal narrowing. The patient was managed conservatively with analgesia and carvedilol for portal hypertension and subsequently experienced complete resolution of back
Birara ED +8 more
europepmc +2 more sources
Using an artificial intelligence-based device to investigate pain outcomes in robotic prostatectomy at low pressure pneumoperitoneum: The RALP clinical trial. [PDF]
Abstract Objective This study aims to investigate any differences in the levels of intra‐operative (measured by an artificial intelligence device) and post‐operative pain between two different abdominal insufflators (AirSeal vs Stryker) used for a low‐pressure pneumoperitoneum robotic prostatectomy.
Vasdev N +18 more
europepmc +2 more sources
The Effect Of The Valveless Pulse Combustor’s Design Components On Its Performance And NOx Emissions
The goal of this research is to develop a pulse combustion simulation model in order to determine the parameters that influence the pulse combustor’s performance when the design geometry is optimized.
Said M. A. Ibrahim +2 more
doaj +1 more source
Design and Fabrication of Pneumatically Actuated Valveless Pumps
In this study, a valveless pump was successfully designed and fabricated for the purpose of medium transportation. Different from traditional pumps, the newly designed pump utilizes an actuated or a deflected membrane, and it serves as the function of a ...
Jr-Lung Lin
doaj +1 more source
Building Valveless Impedance Pumps From Biological Components: Progress and Challenges
Valveless pumping based on Liebau mechanism entails asymmetrical positioning of the compression site relative to the attachment sites of the pump’s elastic segment to the rest of the circuit.
Narine Sarvazyan
doaj +1 more source
Design and Analysis of a Cardioid Flow Tube Valveless Piezoelectric Pump for Medical Applications
Piezoelectric pumps play an important role in modern medical technology. To improve the flow rate of valveless piezoelectric pumps with flow tube structures and promote the miniaturization and integration of their designs, a cardioid flow tube valveless ...
Jialong Wang +8 more
doaj +1 more source
Novel characteristics of valveless pumping [PDF]
This study investigates the occurrence of valveless pumping in a fluid-filled system consisting of two open tanks connected by an elastic tube. We show that directional flow can be achieved by introducing a periodic pinching applied at an asymmetrical location along the tube, and that the flow direction depends on the pumping frequency.
Timmermann, Stine, Ottesen, Johnny T.
openaire +2 more sources
Positive Periodic Solution for Pipe/Tank Flow Configurations with Friction
In this article, we study a periodic boundary value problem related to valveless pumping. The valveless pumping is described by the unidirectional flow of liquid in a system.
Haiqing Du, Xiaojing Wang, Bo Du
doaj +1 more source
Analysis of the characteristics of valveless piezoelectric pump with crescent dune bluff body
To improve the output flow characteristics of the piezoelectric pump in one direction, a new valveless piezoelectric pump with a crescent dune bluff body has been proposed.
Changxiong Xie +5 more
doaj +1 more source
Research on a Piezoelectric Pump with Flexible Valves
Imitating the structure of the venous valve and its characteristics of passive opening and closing with changes in heart pressure, a piezoelectric pump with flexible valves (PPFV) was designed. Firstly, the structure and the working principle of the PPFV
Weiqing Huang +7 more
doaj +1 more source

