Refrigerants for vapour compression refrigeration systems
Resonance, 2012With the mandate of Montreal Protocol banning ozone depleting substances, and Kyoto Protocol later on curtailing the use of substances which contribute to global warming, conventional refrigerants are to be replaced by environment-friendly working fluids.
G. Venkatarathnam, S. Srinivasa Murthy
openaire +1 more source
Energy conservation in vapour compression refrigeration system using vapour injection technique
Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, 2020In modern days, the vapour compression refrigeration system is followed in almost all air-conditioning applications. Due to the high ambient temperature during extreme summer conditions, the commercial vapour compression refrigeration system made with cost competitiveness are not in a position to meet the required indoor conditions (27°C Dry Bulb ...
Chandramohan Rajamani +1 more
openaire +1 more source
Experimental Analysis on Vapour Compression-Thermoelectric Hybrid Refrigeration System
2015 7th International Conference on Emerging Trends in Engineering & Technology (ICETET), 2015Two methods of refrigeration-good Coefficient of performance Vapour compression refrigeration method with good inside temperature control Thermoelectric refrigeration method are combined together in a single setup. The heat fluxes generated from the thermoelectric system are utilized by the vapour compression refrigeration system during the phase ...
Siraj Y. Sayyad, U. S. Wankhede
openaire +1 more source
Comparison of Various Alternative Refrigerants for Vapour Compression Refrigeration Systems
ASME/JSME 2011 8th Thermal Engineering Joint Conference, 2011Single-stage vapour compression refrigeration system was compared with an actual vapour compression cycle, single-stage process with internal heat exchanger, and a two-stage process with economiser using the refrigerants of HCFC-22, CFC-502 and their alternatives such as HFC-134a, HFC-32, HFC-152a, HFC-404A, HFC-407C, HFC-507, HFC-410A.
WONGWISES, Somchai +1 more
openaire +2 more sources
ANALYSIS OF A VAPOUR COMPRESSION REFRIGERATION SYSTEM WORKING WITH R22
International Journal of Modern Manufacturing Technologies, 2023Marine refrigeration has to comply with environmental constraints and with efficiency improvement as well. R22 was a refrigerant governing marine refrigeration systems. After 2020, it is legally in use in old systems, relying on recycled supplies, because of its poor environmental properties.
openaire +1 more source
A review on expanders and their performance in vapour compression refrigeration systems
International Journal of Refrigeration, 2019Abstract This paper reviews progress reported in the open literature of the use of expanders to recover expansion power to improve the energy efficiency of vapour compression refrigeration systems. Pioneering works in the field are first discussed, and then a variety of expander mechanisms, including reciprocating piston, rolling piston, rotary vane,
Anarghya Ananda Murthy +3 more
openaire +1 more source
Analysis of a solar assisted vapour compression cooling system
Renewable Energy, 2013Exploitation of solar energy is becoming increasingly popular thanks to the potential saving on energy costs and to widespread environmental friendly policies. In this context, solar cooling is particularly interesting since greater cooling loads are usually needed in areas where the solar radiation is more abundant and during sunny seasons.
CHESI, ANDREA +3 more
openaire +3 more sources
Analysis of vapour-compression refrigerating systems
2011The aim of this paper is to show the authors proposal for steady state numerical simulation of Vapour-Compression Refrigerating Systems (dry expansion, liquid overfeed systems, ...). The developed tool allows using different levels of simulation for some elements (compressors, pipes, etc.) as well as the possibility of use different kind of expansion ...
Sadurní Caballol, Alexandre +3 more
openaire +1 more source
Thermoeconomic study of a system for pollutant concentration with mechanical vapour compression
Applied Thermal Engineering, 2005The concentration with mechanical vapour compression (MVC) is one of the techniques recommended commonly in the industry for advantages that consist mainly in low consumption of electricity. Several books are talking about the comparative study of energy and economic costs of the equipped installations, and general comparison with other technical ...
S. Hayani Mounir, M. Feidt, C. Vasse
openaire +1 more source
Thermodynamic Analysis of Two-Stage Vapour Compression Refrigeration System
Global Sci-Tech, 2016One of the most important and much needed concerns shown by the researchers ’world over is related to energy. And there are several aspects related to energy on which researches are focusing e.g. optimal use of energy, new or renewable sources of energy and reuse or recovery of waste energy etc.
Ajaz Alam, Subodh Kumar
openaire +1 more source

