Results 71 to 80 of about 144,349 (254)
Gellan gum fluid gel (FG) enables controlled ocular delivery of mesenchymal stromal cell (MSC)‐derived extracellular vesicles (EV). Its shear‐thinning, solid‐liquid‐solid rheology ensures prolonged ocular retention. Sustained MSC‐EV release (∼18% in 6 hrs) supports effective EV ocular delivery.
Seyedmohammad Moosavizadeh +7 more
wiley +1 more source
Background and Aims Femoral artery access is widely used despite recent increase in radial access for percutaneous coronary interventions (PCI). Femoral artery closure devices are used to shorten vascular closure time and reduce bleeding.
Wesley L. Anderson +11 more
doaj +1 more source
Rapid Fabrication of Self‐Propelled and Steerable Magnetic Microcatheters for Precision Medicine
A rapid Joule heating fabrication method for the production of self‐propelling, adaptive microcatheters, with tunable stiffness and integrated microfluidic channels is presented. Demonstrated through three microrobotic designs, including a steerable guiding catheter, an untethered wave‐crawling TubeBot, and a distal‐end propelled microcatheter, it was ...
Zhi Chen +5 more
wiley +1 more source
Vascular closure devices: the jury is still out
Transcatheter aortic valve implantation (TAVI) is an established treatment for elderly patients with severe symptomatic aortic stenosis. Currently, most procedures are performed through transfemoral transcatheter aortic valve implantation (TF-TAVI) under
Juan M. Ruiz-Nodar +1 more
doaj +1 more source
Flexible Dielectric Acoustic Resonator Patch for Tissue Regeneration
A flexible dielectric acoustic resonator patch enables MHz‐range ultrasound generation through resonance amplification without using piezoelectric materials. Conformal integration on a curved substrate allows efficient acoustic delivery to tissue‐mimicking environments.
Donyoung Kang +7 more
wiley +1 more source
Background Three types of central venous access devices (CVADs)—peripherally inserted central catheters (PICCs), skin-tunnelled central catheters (Hickman-type devices), and implantable chest wall Ports (Ports)—are routinely used in the intravenous ...
Caoimhe Ryan +5 more
doaj +1 more source
A wearable electrochemical microneedle patch integrates Prussian Blue redox transduction with molecularly imprinted polymer recognition for reagent‐free sampling and detection of thrombo‐inflammatory biomarkers in dermal interstitial fluid. The platform tracks thrombin and inflammatory cytokines with sensitive in vitro, ex vivo, and in vivo performance,
Mahmoud Ayman Saleh +11 more
wiley +1 more source
SPARC (spatio‐chimeric, plasma‐based, anisotropic, and shear‐responsive construct) that integrates myogenic and vascular microenvironments within a single construct. The dual‐modulus matrix directs aligned myotube formation and endothelial network development, enabling a vascularized muscle implant that seamlessly anastomoses with host tissue and ...
Su Hyun Jung +6 more
wiley +1 more source
Hydrogel‐Based Airway‐on‐Tube With Perfusable Endothelial Lumen and Outward Epithelialization
A hydrogel‐based airway‐on‐tube platform featuring a perfusable endothelial lumen and outward epithelialization is presented. The system supports primary human bronchial epithelial and lung microvascular endothelial coculture under air‐liquid interface conditions.
Ali Doryab +8 more
wiley +1 more source
Oxygen‐releasing hydrogels are widely used to support cell survival in 3D cultures and to promote wound healing. However, incorporating catalase to convert H2O2 into O2 often generates additional oxygen bubbles, leading to material instability which rarely addressed.
Sukulya Bunuasunthon +3 more
wiley +1 more source