Results 41 to 50 of about 8,537 (186)

CFD assessments within strongly transient domains [PDF]

open access: yes, 2007
Assessments based on CFD snapshots of stable conditions within strongly transient domains do not address many aspects of performance associated with occupant interventions, control actions or changing climate. Such domains (e.g.
Hand, J., Samuel, A.A.A.
core  

Impact of Climate Change: Environmental Assessment of Passive Solutions in a Single-Family Home in Southern Spain [PDF]

open access: yes, 2018
According to the IPCC Climate Change projections by 2050 temperatures in southern Spain will have increased noticeably during the summer. Housing—in its current form—will not be able to provide a suitable response to this new climate scenario, and will ...
Escandón Ramírez, Rocío   +5 more
core   +1 more source

Experimental and Numerical Investigation of Cedar Façade Flame Spread With Respect to Sidewall

open access: yesFire and Materials, EarlyView.
ABSTRACT In response to growing energy conservation and carbon neutrality efforts, façade systems incorporating wooden materials have attracted increasing attention, which in turn raises concerns about their combustibility. This study presents a combined experimental and numerical investigation of flame spread along cedar façades.
Xukun Sun   +6 more
wiley   +1 more source

Biomimetic Opaque Ventilated Façade for Low-Rise Buildings in Hot Arid Climate

open access: yesBuildings
Enhancing the thermal performance of building façades is vital for reducing energy demand in hot desert climates, where envelope heat gain increases cooling loads.
Ahmed Alyahya, Simon Lannon, Wassim Jabi
doaj   +1 more source

An Experimental Investigation on the Impact of Burner Height and Location on the Characteristics of Externally Venting Flames

open access: yesFire and Materials, EarlyView.
ABSTRACT Fire sources in actual compartment fires exhibit a predominantly uneven spatial distribution. In this context, the impact of the height and location of the fire source, as well as the heat release rate (HRR) of the fire, on the thermal characteristics of Externally Venting Flames (EVF) is experimentally investigated.
Dionysios I. Kolaitis   +1 more
wiley   +1 more source

Measurement of the Green Façade Prototype in a Climate Chamber: Impact of Watering Regime on the Surface Temperatures

open access: yesEnergies, 2022
Green façades with an active water regime and the water flowing through the substrate itself are not common. This system reduces the temperatures and incorporates the evapotranspiration, which could be more effective than by the regular green façades ...
Peter Juras, Pavol Durica
doaj   +1 more source

CFD supported modelling of double skin facades in hot arid climates [PDF]

open access: yes, 2005
Previous simulations predict the possibility of reducing cooling demands in office buildings in hot arid areas if a selective double skin facade is used.
Hamza, Neveen, Underwood, Chris
core  

Finalisation of the European Approach to Assess the Fire Performance of Facades—Brief Information on the Outcome of the Project

open access: yesFire and Materials, EarlyView.
ABSTRACT This research was conducted within the framework of project SI2.825082, funded by the European Commission—DG GROW. The project's objective was to finalise a European approach for assessing the fire performance of façades under medium and large fire exposure conditions.
Péter Tóth   +7 more
wiley   +1 more source

Fire Performance of Ventilated Rendered Facades with EPS Insulation: Full-Scale DIN-Type Evaluation and Influence of Cavities on Flame Spread

open access: yesFire
The fire performance of ventilated facade systems incorporating combustible insulation remains a critical issue in contemporary building design. This study presents a full-scale natural-fire test of a ventilated, rendered facade system containing 150 mm ...
Aušra Stankiuvienė, Ritoldas Šukys
doaj   +1 more source

Vertical safe separation distance between openings in multi-storey buildings having a fire resistant spandrel

open access: yesMATEC Web of Conferences, 2016
A novel comprehensive methodology is presented for the determination of the vertical separation distance between floor glazing openings in buildings having a fire resistant non-flammable spandrel.
Delichatsios Michael A   +3 more
doaj   +1 more source