Results 61 to 70 of about 3,890,110 (215)

Hydrogel‐Based Airway‐on‐Tube With Perfusable Endothelial Lumen and Outward Epithelialization

open access: yesAdvanced Materials, EarlyView.
A hydrogel‐based airway‐on‐tube platform featuring a perfusable endothelial lumen and outward epithelialization is presented. The system supports primary human bronchial epithelial and lung microvascular endothelial coculture under air‐liquid interface conditions.
Ali Doryab   +8 more
wiley   +1 more source

Ventilation efficiencies of a desk-edge-mounted task ventilation system [PDF]

open access: yes, 2002
In chamber experiments, we investigated the effectiveness of a task ventilation system with an air supply nozzle located underneath the front edge of a desk and directing air toward a heated mannequin seated at the desk. The task ventilation system provided outside air, while another ventilation system provided additional space cooling but no outside ...
Faulkner, David   +3 more
openaire   +4 more sources

Advances in Bio‐Integrated Edge Computing Systems for Smart and Connected Health

open access: yesAdvanced Materials, EarlyView.
This review explores advances in bio‐integrated edge computing for healthcare, focusing on co‐designing computing, sensing, and energy strategies to overcome integration and power challenges for optimized, decentralized operation. ABSTRACT Recent advances in bio‐integrated healthcare technologies have enabled continuous, high‐resolution monitoring and ...
Gyuwon Kim   +4 more
wiley   +1 more source

Analysis of Ventilation Efficiency and Effective Ventilation Flow Rate for Wind-driven Single-sided Ventilation Buildings

open access: yesAerosol and Air Quality Research, 2020
Natural ventilation can be categorized into single-sided ventilation and cross-ventilation. Based on the air flow mechanism of a single-sided wind-driven natural ventilation, the effective ventilation flow rates in buildings are different from the air ...
Junli Zhou   +4 more
doaj   +1 more source

Efficient ventilation in office rooms

open access: yesEnvironment International, 1982
Abstract Results from a two-box model for calculation of tracer gas concentrations in rooms are given and consequences of different definitions of “ventilation efficiency” are discussed. Results from three different series of experiments are presented.
Tor-Göran Malmström, Ander Ahlgren
openaire   +1 more source

Ionic Liquid (IL) Compatibilization of Macropore‐Infused Nanocomposite Emulsion Thermosets (MINETs) for Structural Ion Transport

open access: yesAdvanced Materials Interfaces, EarlyView.
Macropore‐infused nanocomposite emulsion thermosets (MINETs) offer tunable multifunctionality due to their incorporation of structural resin, functional nanoparticles, and working fluid stabilized by surfactant. Here we show that if ionic liquid working fluids are introduced, structural capacitive (conductive particles) or separator (insulating ...
Bryan Llumiquinga   +6 more
wiley   +1 more source

Improvement of summer comfort by passive cooling with increased ventilation and night cooling [PDF]

open access: yes, 2013
The study describes the potential improvement of summer comfort and reduction of energy consumption that can be achieved by adopting passive cooling solutions, such as daytime comfort ventilation with increased air velocities and night cooling, in ...
Pellegrini, Tommaso
core  

Continuum Robots in Surgery: From Engineering Design to Clinical Practice

open access: yesAdvanced Robotics Research, EarlyView.
The hyper‐redundant nature of continuum robot structures enables near‐infinite degrees of freedom leading to immense potential for medical applications. This review provides a historical background of continuum robots and novel ideas shaping their progress to current structural design, sensing technology, modeling techniques, and control methods.
Griffin Smith   +6 more
wiley   +1 more source

Computational Fluid Dynamics-based simulation to analyse viral dispersion and spatial resilience in Tanzania [PDF]

open access: yesArchitecture Papers of the Faculty of Architecture and Design STU
An airborne transmission of COVID-19 in resource-constrained healthcare facilities, such as isolation centres in Tanzania, poses significant infection risks owing to insufficient ventilation.
Benson Vedasto Karumuna, Ph.D   +1 more
doaj   +1 more source

Energy-Efficient Mine Ventilation Practices

open access: yes, 2017
Energy efficiency in mine ventilation, which is responsible for a substantial amount of total energy consumption, is of paramount concern in underground mining.
Nuray Demirel, Demirel, Nuray
core   +1 more source

Home - About - Disclaimer - Privacy