Results 101 to 110 of about 68,243 (289)

Beneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation

open access: yesJournal of Cardiothoracic Surgery, 2012
Background Optimal management of acute right heart failure following the implantation of a left ventricular assist device requires a reliable estimation of left ventricular preload and contractility.
Spiliopoulos Sotirios   +3 more
doaj   +1 more source

Precision Diagnostics in Sports‐Related Traumatic Brain Injury: Pathophysiology, Biomarker Development and Emerging Technologies

open access: yesAdvanced Sensor Research, EarlyView.
Sports‐related traumatic brain injuries (TBIs) remain underdiagnosed, within amateur athletic cohorts. This review critically synthesises recent advancements in AI‐assisted neuroimaging, blood‐based biomarker profiling, wearable biosensing platforms for early detection, injury stratification, and longitudinal surveillance of TBIs.
Daniel Nicol   +3 more
wiley   +1 more source

Vascular device interaction with the endothelium [PDF]

open access: yes, 2008
Copyright @ 2008 Elsevier. This is the post-print version of the article.Cerebral stents and Intra Aortic Balloon Pumps (IABP) are examples of mechanical devices that are inserted into arteries to restore flows to clinically healthy states. The stent and
Atherton, MA   +4 more
core   +2 more sources

Improvement of Hemocompatibility in Passive Cardiovascular Implant Devices

open access: yesAdvanced Therapeutics, EarlyView.
With the ever‐increasing reliance on cardiovascular devices and implants, minimizing their impact on blood is vital for their continued success. This review investigates the common methods of tackling this challenge through careful selections of material and surface modifications.
Shiyen L. Perera   +4 more
wiley   +1 more source

Methodological Study of Reliability Test of Percutaneous Ventricular Assist Device

open access: yesZhongguo yiliao qixie zazhi
Prior to clinical application, reliability of percutaneous ventricular assist devices(pVAD) requires to be tested systematically. Currently, there's a lack of dedicated reliability testing equipment and methodologies for pVAD.
Xun LIU   +3 more
doaj   +1 more source

Left Ventricular Assist Device Implantation via Bi-Thoracotomy Technique: A Single-Center Perspective [PDF]

open access: gold, 2021
Elizabeth M. Stoeckl   +3 more
openalex   +1 more source

Subventricular Zone‐on‐a‐Chip: A Model to Study Neurogenesis Disruption in Neonatal Intraventricular Hemorrhage

open access: yesAdvanced Science, EarlyView.
A human subventricular zone‐on‐a‐chip is developed to model intraventricular hemorrhage (IVH) in preterm infants. This platform enables the study of inflammation‐driven neurogenic disruption. Exposure to hemorrhagic cerebrospinal fluid and red blood cell lysate activated inflammatory pathways, with IL1B emerging as a key mediator.
Laura Nicoleti Zamproni   +6 more
wiley   +1 more source

Improving the Quality and Efficiency of the Medicare Program Through Coverage Policy [PDF]

open access: yes, 2011
Outlines Medicare coverage and payment policy on new technologies and recommends changes that could help achieve the Triple Aim goals of enhancing the individual experience of care, improving population health, and reducing per capita costs of ...
Penny E. Mohr   +3 more
core  

FMO2 Promotes Angiogenesis via Regulation of N‐Acetylornithine

open access: yesAdvanced Science, EarlyView.
This study identifies flavin‐containing monooxygenase 2 (FMO2) as a novel proangiogenic regulator in endothelial cells. Targeted FMO2 ablation impairs vessel sprouting, whereas its compensation potently enhances angiogenesis. Metabolomics and single‐cell sequencing reveal that FMO2 drives vascular growth via the N‐acetylornithine/ATF3/NOTCH1 axis ...
Jingyi Wang   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy