Results 71 to 80 of about 176,246 (351)
Materials Advances in Devices for Heart Disease Interventions
This review examines the crucial role of materials in heart disease interventions, focusing on strategies for monitoring, managing, and repairing heart conditions. It discusses the material requirements for medical devices, highlighting recent innovations and their impact on cardiovascular health.
Gagan K. Jalandhra+11 more
wiley +1 more source
Abstract Background Heart failure (HF) is often comorbid with sleep disordered breathing (SDB). This prospective study investigated the prevalence, clinical characteristics, and predictors of SDB in hospitalized HF patients. Methods Sleep studies were performed on hospitalized HF patients from January 2015 to February 2019.
Boping Huang+8 more
wiley +1 more source
Electromagnetic interference (EMI) between implantable left ventricular assist devices and cardiac implantable electronic devices has been observed. We demonstrated the first case of EMI between a percutaneous ventricular assist device and an implantable
Kosuke Takahari, MD+9 more
doaj
Transcatheter valvular therapies in patients with left ventricular assist devices
Aortic, mitral and tricuspid valve regurgitation are commonly encountered in patients with continuous-flow left ventricular assist devices (CF-LVADs). These valvular heart conditions either develop prior to CF-LVAD implantation or are induced by the pump
Olina Dagher+19 more
doaj +1 more source
Ventricular Assist Devices [PDF]
The need for mechanical assistance of the failing heart, whether acute after a myocardial infarction or permanent in patients with end-stage heart failure, has increased with improvements in medical therapy and a growing aged population. Over the past few decades, much progress has been made in the development and refinement of ventricular assist ...
Garrick C. Stewart+3 more
openaire +2 more sources
In Vitro and In Silico Characterization of the Aggregation of Thrombi on Ventricular Assist Device Cannula [PDF]
The unacceptably high stroke rate of HeartMate III VAD without signs of adherent pump thrombosis is hypothesized to be the result of the thrombi originating on the inflow cannula, ingesting and ejecting emboli from the VAD. Therefore, inflow cannula thrombosis has been an emerging focus.
arxiv
Anticoagulant properties are critical for blood‐compatible materials, and anticoagulant coatings are a common key issue for blood‐contacting medical devices. In this study, a block copolymer poly(2‐methacrylenoxyethyl phosphocholine‐b‐glycidyl) (PMPC‐b‐GMA) is synthesized, using reversible addition‐fragmentation chain transfer polymerization (RAFT) and
Xinli Lu+6 more
wiley +1 more source
Abstract Background Antibody–drug conjugates (ADCs) have complex molecular structures and have been tested in numerous clinical trials. Therefore, understanding the mechanisms of their toxicity when applied in medical practice is of high importance. Methods In a systematic review and meta‐analysis of data gathered from different scientific databases ...
Youwen Zhu+3 more
wiley +1 more source
Current Trends in Implantable Left Ventricular Assist Devices
The shortage of appropriate donor organs and the expanding pool of patients waiting for heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support.
Jens Garbade+3 more
doaj +1 more source
Ventricular assist devices for heart failure [PDF]
Background: Heart failure is a clinical syndrome of major epidemiological and economical importance. In Germany as in other industrialised countries it is one of the leading causes of mortality, morbidity and disability.
Angermayr, Lucia+2 more
core +2 more sources