Results 41 to 50 of about 7,424,509 (170)

A Novel Power Transformer Condition Monitoring System Based on Wide-Band Measurement of Core Earth Signals and Correlation Analysis With Multi-Source Data

open access: yesIEEE Access, 2019
On-line condition monitoring and real-time fault detection are essential to protect power transformers from unscheduled outage of services. The core earth signals (CES) are valuable for fault detection and diagnosis of power transformers, as they are ...
Xuezhi Ke   +3 more
doaj   +1 more source

Arc Resistance Enhancement of Converter Transformer Tank Through Structural Improvements: Simulation and Experimental Validation

open access: yesHigh Voltage, EarlyView.
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang   +5 more
wiley   +1 more source

Application of thyristor controlled phase shifting transformer excitation impedance switching control to suppress short-circuit fault current level

open access: yesJournal of Modern Power Systems and Clean Energy, 2018
Short-circuit fault current suppression is a very important issue in modern large-interconnected power networks. Conventional short-circuit current limiters, such as superconducting fault current limiters, have to increase additional equipment ...
Jun LIU   +5 more
doaj   +1 more source

Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China

open access: yesHigh Voltage, EarlyView.
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li   +9 more
wiley   +1 more source

Research on Lightning Overvoltage Characteristics of High-Voltage Diode Rectifier

open access: yes, 2022
Failure of the high-voltage diode rectifier caused by lightning will cause huge losses. The traditional analysis of overvoltage induced by the high-voltage diode rectifier shell under lightning stroke cannot adapt to the overvoltage process caused by ...
Guoping Peng   +6 more
core   +1 more source

Mechanism of Quasi‐Power‐Frequency Resonant Overvoltage Triggered by Multiple Lightning Strikes in High‐Voltage Alternating Current Systems Equipped With Shunt Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang   +7 more
wiley   +1 more source

Zero‐Current Switching Based Model Predictive Control of a Double‐Extended Overlapped Alternate Arm Converter Used in the VSC–HVDC System

open access: yesHigh Voltage, EarlyView.
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley   +1 more source

Comprehensive Design and Experimental Validation of 30 kV Ultra‐Fast Flexible Controllable Arresters for HVDC Systems

open access: yesHigh Voltage, EarlyView.
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang   +4 more
wiley   +1 more source

Simulation and analysis of a gas insulated switchgear explosion accident caused by a failure of high-voltage circuit breaker in a thermal power plant

open access: yesThe Journal of Engineering, 2019
This study analyses a gas insulated switchgear explosion accident caused by a failure of the circuit breaker (CB) in a thermal power plant, which resulted in the explosion of the CB and the burning of the potential transformer (PT).
Xun Zhang   +6 more
doaj   +1 more source

Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device

open access: yesHigh Voltage, EarlyView.
ABSTRACT Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc ...
Yeqiang Deng   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy