Results 81 to 90 of about 6,661,100 (99)
Comparison Between Suppressing Approaches of Very Fast Transients in Gas-Insulated Substations (GIS)
In this paper, first transient waves in the gas-insulated substation (GIS) are analyzed and methods for suppression of very fast transients (VFTs) in GISs are introduced. For suppressing VFTs, four methods are presented, including suppression by terminal
Hassan Nouri, Michael Negnevitsky
exaly +2 more sources
Voltage Stress in a Transformer Winding During Very Fast Transients Caused by Breaker Closing Event
Transformers connected at the medium-voltage level in cable grids, such as wind park collection grids and industrial grids, are exposed to the stress of very fast transients.
Torbjörn Thiringer, Tarik Abdulahovic
exaly +2 more sources
Qualifying a Transient Recorder for Traceable Measurements of Very Fast Transients
This paper presents the qualification of a transient recorder used in a system for traceable measurements of Very Fast Transients. The system is designed for traceable measurements of VFT up to 100 kV, having a target settling time < 10 ns, a peak ...
Alf-Peter Elg
exaly +2 more sources
Some of the next articles are maybe not open access.
IEEE International Symposium on Electrical Insulation, 2002
The time lags in SF/sub 6/ and SF/sub 6//N/sub 2/ mixtures for gaps with strong nonuniform field distribution, stressed by very fast transient voltages (VFTs), were investigated. The shape of the applied voltages was used to simulate the voltages that can occur by switch operation in gas-insulated substations (GISs).
W. Pfeiffer, V. Zimmer, P. Zipfl
openaire +1 more source
The time lags in SF/sub 6/ and SF/sub 6//N/sub 2/ mixtures for gaps with strong nonuniform field distribution, stressed by very fast transient voltages (VFTs), were investigated. The shape of the applied voltages was used to simulate the voltages that can occur by switch operation in gas-insulated substations (GISs).
W. Pfeiffer, V. Zimmer, P. Zipfl
openaire +1 more source
Very Fast Transients in a 500 kV Gas-Insulated Substation
IEEE Transactions on Power Delivery, 2019Haoyan Xue +2 more
exaly +2 more sources
3D Full-Maxwell Simulations of Very Fast Transients in GIS
IEEE Transactions on Magnetics, 2011Jasmin Smajic
exaly
Analysis Model for VFT Considering the Effect of Nonuniform Distribution of Residual Charge
IEEE Transactions on Power Delivery, 2017Binxian Lu
exaly
Simulation-Based Design of HF Resonators for Damping Very Fast Transients in GIS
IEEE Transactions on Power Delivery, 2014Stefan Tenbohlen +2 more
exaly
Electromagnetic disturbances in gas-insulated substations and VFT calculations
Electric Power Systems Research, 2018Masashi Natsui +2 more
exaly