Results 61 to 70 of about 2,951,207 (190)

Transient vibration analysis of a completely free plate using modes obtained by Gorman's superposition method [PDF]

open access: yes, 2010
This paper shows that the transient response of a plate undergoing flexural vibration can be calculated accurately and efficiently using the natural frequencies and modes obtained from the superposition method.
Ilanko, Sinniah   +3 more
core   +1 more source

Technical Feasibility Study of Autonomous Field Robot‐Based on‐the‐go Assessment of Soil Nutrients Using Ion‐Sensitive Field‐Effect Transistors

open access: yesAdvanced Robotics Research, EarlyView.
Autonomous field robots equipped with ISFET‐based sensors enable rapid, spatially resolved soil nutrient analysis directly in the field. An automated system based on the BoniRob platform is presented for standardized on‐site extraction and measurement of key macronutrients and soil pH.
Vadim Riedel   +3 more
wiley   +1 more source

Flexible Sensors for Robotics Tactile Perception: A Review

open access: yesAdvanced Robotics Research, EarlyView.
Flexible tactile sensing for robotics is reviewed through four interconnected dimensions. Physical mechanisms include piezoresistive, capacitive, piezoelectric, triboelectric, iontronic, and optical sensing. Structural design includes bioinspired, defect‐based, and MEMS‐based tactile systems.
Yu Song, Ying Chen, Yihao Chen, Xue Feng
wiley   +1 more source

VIBRATION OF MINDLIN PLATES SYMMETRICALLY COLUMN-SUPPORTED AT 4 POINTS

open access: yes, 1993
This paper deals with the free vibration characteristics of Mindlin plates that are symmetrically column-supported at four points. The finite difference technique, based on the energy approach, is used.
AKSU, G, G. Aksu
core   +1 more source

Distributed Micropneumatic Sensors for Soft Robots to Detect Touch and Pose

open access: yesAdvanced Robotics Research, EarlyView.
Soft robots need integrated touch and pose sensing for safe and reliable operation. This work presents a three‐fingered soft gripper with 18 micropneumatic sensors made from the same materials as its pneumatic actuators. By measuring airflow resistance changes in deforming microchannels of the sensors, finger pose and contact are detected, enabling ...
Vilma Lampinen   +3 more
wiley   +1 more source

Performance of tuned liquid column dampers considering maximum liquid motion in seismic vibration control of structures

open access: yes, 2012
The optimum design of tuned liquid column damper (TLCD) is usually performed by minimizing the maximum response of structure subjected to stochastic earthquake load without imposing any restrictions on the possible maximum oscillation of the liquid ...
Debbarma, R.   +2 more
core   +1 more source

Mitochondria and Neuromast Tagging With Fluorescent Gallium‐Triapine Analogues: In Cellulo MP FLIM and Zebrafish Live Imaging

open access: yesAdvanced Science, EarlyView.
Fluorescent BODIPY‐conjugated thiosemicarbazone ligands and their Ga(III), In(III), and Fe(III) complexes, inspired by Triapine, are developed as theranostic agents. Multiphoton FLIM and confocal microscopy in cancer cells and zebrafish reveal real‐time uptake, mitochondrial localisation, and whilst spectroscopic assays indicated preserved complex ...
Megan J. Green   +15 more
wiley   +1 more source

Mitigation of wind-induced vibration of a tall residential building using liquid column vibration absorber [PDF]

open access: yes, 2016
The most important thing in applying mass type dampers including Liquid Column Vibration Absorber (LCVA) is tuning its natural frequency to an optimum value which is a function of the natural frequency of the building and the mass ratio of damper to the ...
Hongjin Kim, Bong-Ho Cho, Eunjong Yu
core   +1 more source

Combating Inflammation and Promoting Anabolism in Osteoarthritic Cartilage Defect With an MMP13‐Sensing Dual‐Drug Scaffold

open access: yesAdvanced Science, EarlyView.
ABSTRACT Osteoarthritis (OA) is a widespread degenerative joint condition marked by progressive cartilage breakdown, and a chronic inflammatory microenvironment, where conventional therapies largely fail to halt disease progression. To address this unmet need, an intra‐articularly implantable, disease‐responsive scaffold was developed for combinatorial
Zhen Zhang   +6 more
wiley   +1 more source

Vibration Control of a Column Using a Gyroscope

open access: yes, 2015
Inthispaper, the characteristics of a vibration control system utilizing a gyro and its effectiveness in the control of the motion subjected to a seismic ground motion acceleration were studied.
Cuvalci, O., Unker, F.
core   +1 more source

Home - About - Disclaimer - Privacy