Results 171 to 180 of about 1,306 (252)

Extrusion Bioprinting for Wound Healing: Innovations in Functionalized Bioinks and Bioprinting Technology

open access: yesAdvanced Materials Technologies, EarlyView.
Extrusion‐based bioprinting (EBB) has emerged as a versatile biofabrication platform capable of precisely depositing bioinks composed of biomaterials, cells, and bioactive agents to generate patient‐specific, biomimetic skin constructs. This paper presents a state‐of‐the‐art and forward‐looking overview of EBB for wound healing, encompassing printing ...
Hien‐Phuong Le   +4 more
wiley   +1 more source

Electroactive 3D Porous Graphene Foam Impedimetric Biosensor for Ultrasensitive Detection of MCF‐7‐Cells‐Derived Extracellular Vesicles in Human Serum

open access: yesAdvanced Materials Technologies, EarlyView.
A label‐free impedimetric biosensor based on electroactive 3D porous graphene foam enables ultrasensitive and selective detection of CD81 protein and MCF‐7 cell‐derived extracellular vesicles in human serum. Detection limits of 0.048 fg/mL for CD81 and ∼24 EVs/mL are achieved, demonstrating a robust platform for selective, label‐free, and ...
Michael Robert Furness   +11 more
wiley   +1 more source

In Situ Two‐Dimensional Residual Stress Characterization of Thin Films

open access: yesAdvanced Materials Technologies, EarlyView.
An integrated in situ curvature metrology platform combining speckle‐based curvature optical metrology (SCOM) with multi‐beam optical sensors (MOS) enables spatially resolved two‐dimensional curvature mapping of thick sputtered coatings. The SCOM technique provides excellent agreement with MOS while providing an extended measurable curvature range ...
Wai Jue Tan   +6 more
wiley   +1 more source

Strain‐Activated Mechanical Metamaterial With Programmable Dual‐Phase Stiffness and Enhanced Energy Absorption

open access: yesAdvanced Materials Technologies, EarlyView.
A strain‐activated mechanical metamaterial is developed to achieve programmable dual‐phase stiffness through an intrinsic geometric locking mechanism. Finite element modeling and parametric analysis identify the key design parameters governing activation strain, stiffness transition, and energy absorption.
Ramin Yousefi‐Nooraie   +3 more
wiley   +1 more source

WS2 Micro‐Dome Single Photon Source in a Tunable Open Cavity

open access: yesAdvanced Optical Materials, EarlyView.
In this work, a single‐photon source based on WS2 micro‐domes is realized and integrated into an open, tunable optical microcavity. Single‐photon emission from the coupled emitter–cavity system is observed. Detailed analysis shows that a pronounced acoustic phonon emission sideband contributes specifically to the non‐resonant emitter–cavity coupling in
Jens‐Christian Drawer   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy