Results 1 to 10 of about 381,671 (280)

A Review of Evaluation Methods of Standards for Structural Vibration Serviceability Under Crowd Walking

open access: yesBuildings
Structures such as long-span footbridges, floors, and long cantilevers are vulnerable to vibration serviceability problems under crowd walking, which should be taken into consideration during the structural design, operation, and maintenance stages ...
Hui Qian
exaly   +4 more sources

Human-Induced Vibration Serviceability: From Dynamic Load Measurement towards the Performance-Based Structural Design

open access: yesBuildings, 2023
Since the well-known Millennium bridge accident happened at the beginning of this century, both researchers and engineers realized that the human-induced vibration may lead to unaffordable consequences. Although such vibrations hardly threaten the safety
Haoqi Wang   +4 more
doaj   +2 more sources

Wind-induced vibration serviceability of ten multi-storey timber buildings [PDF]

open access: yesOpen Research Europe
Multi-storey timber buildings are prone to wind-induced vibrations, especially due to their lightweight nature, which can lead to occupant discomfort. Vibration serviceability may be a critical design criterion for such structures.
Blaž Kurent, Boštjan Brank
doaj   +2 more sources

Vibration Serviceability Assessment of Floor Structures: Simulation of Human–Structure–Environment Interactions Using Agent-Based Modeling [PDF]

open access: yesSensors
A rapidly growing body of experimental evidence in the literature shows that the effects of humans interacting with vibrating structures, other humans, and their surrounding environment can be critical for reliable estimation of structural vibrations ...
Erfan Shahabpoor   +2 more
doaj   +2 more sources

Progress of ultrasonic vibration-assisted machining surface micro-texture and serviceability

open access: yesJin'gangshi yu moliao moju gongcheng, 2023
Ultrasonic machining, as an effective method to regulate the input external energy, is widely used in surface generation and modification. It can fabricate the microstructure through the precise regulation of interface energy.
Wenbo BIE   +5 more
doaj   +4 more sources

Vibration serviceability limit state of pedestrian bridges [PDF]

open access: yesGrađevinski Materijali i Konstrukcije, 2021
Modern conustructions of pedestrian bridges must satisfy functional and increasingly complex architectural requirements. In order to achieve the attractive design of pedestrian bridges, modern constructions generally differ from older, conventional ...
Ramoul Adam, Spremić Milan
doaj   +2 more sources

Time dependent seismic fragility and serviceability assessment of reinforced concrete frames under chloride induced corrosion [PDF]

open access: yesScientific Reports
Chloride-induced corrosion represents a critical deterioration mechanism for reinforced concrete (RC) structures, yet its time-dependent impact on structural reliability remains insufficiently investigated.
Behrouz Kordtabar   +3 more
doaj   +2 more sources

Experimental Assessment of Human–Structure Interaction in an Urban Pedestrian Footbridge with Multiaxial Dynamic Sensitivity [PDF]

open access: yesSensors
Recent advances in structural engineering have enabled lightweight and slender footbridges. However, these structures are often susceptible to excessive vibrations induced by pedestrian activities, primarily impacting urban footbridge serviceability ...
Bryan Castillo   +4 more
doaj   +2 more sources

Maximal Multivariable Coefficient Analysis between Vibration Limits and Relevant Factors in General Buildings

open access: yesBuildings, 2022
The vibration limit is an essential prerequisite for building vibration serviceability assessment, and various biological/environmental factors affect it deeply.
Lei Cao, Jun Chen
doaj   +1 more source

The Effect of the Environment on the Serviceability of the Cross-Laminated Timber (CLT) Floor: Virtual Reality as a Research Tool

open access: yesAdvances in Civil Engineering, 2022
The environment is one of the factors that may influence occupants’ perception of floor vibration and the assessment of floor serviceability. In this study, laboratory tests were conducted on a 3-ply CLT floor.
Haoyu Huang   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy