Results 121 to 130 of about 584,468 (150)
Some of the next articles are maybe not open access.
Evaluation of vicarious calibration for airborne sensors using RadCalNet
Journal of Applied Remote Sensing, 2020Vicarious calibration approaches using in-situ measurements are key techniques applied to on-orbit remote sensors. The in-situ measurements have advantages in terms of traceability and quantifiable accuracy that make them ideal for inter-consistency studies of on-orbit sensors.
Brian N. Wenny +2 more
openaire +1 more source
Vicarious Calibration of the Meteosat Visible Channel
Journal of Atmospheric and Oceanic Technology, 1993Abstract Postlaunch calibration of the Meteosat visible (VIS) channel has been performed with Meteosat-1, Meteosat-2, and Meteosat-4. The radiance at the satellite radiometer aperture has been determined by independent means and has been related to the simultaneous satellite radiometer count.
Karl-Theodor Kriebel, Volker Amann
openaire +1 more source
Stability of the vicarious cold calibration statistic for the GPM constellation
2010 IEEE International Geoscience and Remote Sensing Symposium, 2010The vicarious cold calibration statistic has been analyzed to determine its stability. Modeled top of atmosphere brightness temperatures representing microwave radiometer observations are computed for the month of July 2005 using a radiative transfer model. The vicarious cold calibration algorithm is applied to the population of brightness temperatures
Rachael Kroodsma +3 more
openaire +1 more source
Vicarious Cold Calibration for Conical Scanning Microwave Imagers
IEEE Transactions on Geoscience and Remote Sensing, 2017Vicarious cold calibration (VCC) for spaceborne microwave radiometers is analyzed and modified for application to conical scanning microwave imagers at frequencies from 6 to 90 GHz. The details of the algorithm are modified to account for additional frequencies and polarizations that were not included in the development of the original algorithm.
Rachael A. Kroodsma +2 more
openaire +1 more source
Vicarious Calibration of the Formosat-2 Remote Sensing Instrument
IEEE Transactions on Geoscience and Remote Sensing, 2010We describe the results of the in-orbit radiometric calibration of the remote sensing instrument (RSI) onboard Formosat-2, based on the ground data collected by the advanced spaceborne thermal emission and reflection radiometer (ASTER) calibration team at Ivanpah Playa and Railroad Valley during the regular field campaigns in 2006 and 2008.
Cheng-Chien Liu +7 more
openaire +1 more source
Calibration of WindSat polarimetric channels with a vicarious cold reference
IEEE Transactions on Geoscience and Remote Sensing, 2006Absolute calibration of WindSat's third and fourth Stokes brightness temperatures (T/sub 3/ and T/sub 4/) is needed at the tenth of Kelvin level in order to adequately resolve their dependence on wind direction. Previous aircraft based fully polarimetric microwave radiometers have generally relied on "circle flights", during which a single area of the ...
Christopher S. Ruf +2 more
openaire +2 more sources
Preflight and Vicarious Calibration of Hyperspectral Imagers
2007Abstract : We developed a calibration plan for a hyperspectral sensor and then designed, built, and calibrated three major instruments to support such calibrations. The instruments included two transfer radiometers, one covering the visible and near infrared using a silicon detector, and another covering the short-wave infrared using a cooled InGaAs ...
S. F. Biggar, K. J. Thome
openaire +1 more source
Evaluation and Application of On-Orbit Calibration of the Automated Vicarious Calibration System
IEEE Transactions on Geoscience and Remote Sensing, 2023Dong Huang +5 more
openaire +2 more sources
Vicarious Calibration of the TUBIN Infrared Sensor Suite
2022 IEEE Sensors, 2022Julian Bartholomäus +3 more
openaire +1 more source
Vicarious calibration of Terra ASTER, MISR, and MODIS
SPIE Proceedings, 2004The Advanced Spaceborne Thermal Emission and Reflection and Radiometer (ASTER), Multi-angle Imaging Spectroradiometer (MISR) and Moderate Resolution Imaging Spectroradiometer (MODIS) are all onboard the Terra platform. An important aspect of the use of MODIS, and other Earth Science Enterprise sensors, has been the characterization and calibration of ...
Kurtis J. Thome +2 more
openaire +1 more source

