Results 181 to 190 of about 3,589,195 (283)

A Cable‐Driven Parallel Wire Robot for Probe Positioning and Tissue Palpation on Curved Phantoms

open access: yesAdvanced Intelligent Systems, EarlyView.
A wearable cable‐driven parallel robot is introduced for autonomous ultrasound probe positioning and soft tissue palpation on curved surfaces. By combining visual feedback with tension‐optimized control, the system achieves millimeter‐scale positioning accuracy while enforcing safety force constraints.
Christina Patterson   +2 more
wiley   +1 more source

LLM‐Based Multimodal Robotic Endoscope Control Framework for Enhancing Human–Robot Interaction in Minimally Invasive Surgery

open access: yesAdvanced Intelligent Systems, EarlyView.
An large language model‐powered multimodal framework is developed for robotic endoscope control. It integrates speech recognition and real‐time instrument tracking, achieving 89.47% command accuracy with ~1s latency for natural human–robot interaction in minimally invasive surgery.
Yisen Huang   +7 more
wiley   +1 more source

Current real-life survival after segmentectomy for lung cancer. [PDF]

open access: yesFront Surg
Cansouline X   +6 more
europepmc   +1 more source

Development of an Inchworm‐Like Dual‐Balloon‐Assisted Colonoscopic Robot Based on a Two‐Segment Extensible Continuum Section

open access: yesAdvanced Intelligent Systems, EarlyView.
This work presents an inchworm‐like dual‐balloon‐assisted colonoscopic robot (IDCR) based on a rod‐driven two‐segment continuum section. The IDCR enables the active straightening of the sigmoid colon through an inchworm‐like locomotion strategy, thereby avoiding loop formation.
Dezhi Song   +4 more
wiley   +1 more source

Crease‐Encoded Soft Origami Chambers: A Unified Design‐to‐Fabrication Framework for Low‐Pressure Pneumatic Joints

open access: yesAdvanced Intelligent Systems, EarlyView.
Origami turns a single silicone chamber into three different soft fluidic actuators. Crease angles alone decide whether it elongates, bends, or twists, and the fully folded chambers are cast monolithically in one day. Below 15 kPa, they reach 268% axial stretch, 72° bending, and 55° twist—no strain‐limiting layers, no rigid reinforcements, no vacuum ...
Alexia Le Gall   +4 more
wiley   +1 more source

A Multidimensional Perspective on Network Conditions in Telesurgery

open access: yesAdvanced Intelligent Systems, EarlyView.
A multidimensional framework systematically evaluates how combined network impairments influence telesurgical performance. By jointly analyzing latency, jitter, bandwidth, and packet loss, the proposed methodology identifies relevant network condition parameters and their interactions, supporting the design of reliable and safe telesurgical systems ...
Florian Heemeyer   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy