Results 241 to 250 of about 202,540 (301)

Multiscale Microscopy via Automation: Dual Magnification Environmental Scanning Electron Microscopy Imaging by Frame Alternation

open access: yesAdvanced Materials Technologies, EarlyView.
An automation interface for environmental scanning electron microscopy (ESEM) enables simultaneous, interlaced data sets via frame‐by‐frame parameter changes. Demonstrated on oscillatory hydrogen oxidation over cobalt (Co) foil, dual‐magnification imaging bridges mesoscopic to microscopic length scales, capturing alternating views of surface dynamics ...
Maurits Vuijk   +7 more
wiley   +1 more source

Graphene‐Interfaced Stretchable Sweat Patch for Multiplexed Electrochemical Monitoring of IL‐6, Glucose, and Calcium Ions

open access: yesAdvanced Materials Technologies, EarlyView.
Flexible sweat sensor patch integrating graphene‑interfaced gold microelectrodes functionalized with bio‑receptors and ion‑selective membrane, coupled with a capillary‑driven microfluidic layer and portable potentiostat electronics for multiplexed monitoring of inflammatory, metabolic, and electrolyte biomarkers in microliter sweat volumes.
Roomia Memon   +4 more
wiley   +1 more source

3D Printed Omniphobic Slippery Liquid Infused Porous Surfaces for Low Surface Tension Repellency

open access: yesAdvanced Materials Technologies, EarlyView.
A 3D printing strategy fabricates omniphobic slippery liquid‐infused porous structures with lubricant reservoirs and interconnected microchannels. A post‐printing surface treatment modifies the porous surface to ensure compatibility with the infused fluorinated lubricant.
Noa Trink, Shlomo Magdassi
wiley   +1 more source

Buckling‐Driven Linearity in Flexible Capacitive Pressure Sensors Based on a Three‐Dimensional Dual‐Pore Polyurethane Structure

open access: yesAdvanced Materials Technologies, EarlyView.
A flexible pressure sensor utilizing a 3D dual‐pore polyurethane structure is developed to overcome the intrinsic trade‐off between sensitivity and linearity. By inducing sequential buckling through distinct pore sizes and shapes, the device achieves highly linear and sensitive responses across a wide pressure range.
Jae Yeong Jang, Jaemin Choi, Young Jung
wiley   +1 more source

Flexible Pressure Sensor With Co‐Optimized Sensitivity and Linearity Based on Gradient Toroidal Microstructures

open access: yesAdvanced Materials Technologies, EarlyView.
A flexible piezoresistive pressure sensor with gradient toroidal CNT/PDMS microstructures is reported. The hierarchical geometry enables sequential electrode contact, achieving a sensitivity of 256.20 kPa−1 and linear response (R2 = 0.99) over 0–1000 kPa.
Rongmei Wang   +8 more
wiley   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Digital video recording

Proceedings of the IEEE, 1995
Through mutual technology transfer between consumer and professional video recorders, the last 20 years has witnessed a rapid evolution from analog to digital recording. Each new digital videotape recorder (VTR) uses different channel coding. This implies that improving the recording density involves the development of new channel-coding schemes ...
M Umemoto, Y Eto
exaly   +2 more sources

Video recording in ophthalmic surgery

Survey of Ophthalmology, 2019
Video recording in ophthalmic surgery has immense potential to drive quality improvement in patient care, ophthalmology training, and research. Not only do surgical videos permit introspective and critical analyses of surgical technique, they also allow for objective assessment, allow for more informative audits, and are an invaluable medium for ...
Shivanand Sheth
exaly   +3 more sources

Video recordings and video polysomnography

2011
Publisher Summary Video polysomnography (VPSG) combines simultaneous polysomnography (PSG) and video- electroencephalography (EEG) to evaluate patients with nocturnal events. This technique has several advantages over routine PSG, including the ability to analyze behavior, correlate behavior with neurophysiologic parameters, and detect epileptiform ...
Nancy, Foldvary-Schaefer, Beth, Malow
openaire   +2 more sources

Video recording.

Electroencephalography and clinical neurophysiology. Supplement, 1985
Two video techniques are commonly used for biomedical monitoring. The simplest technique uses 2 or 3 video cameras with a special-effects generator. The more advanced method uses one video camera with a reformatter, a special-effects generator and a time-code generator.
R J, Porter, S, Sato, R L, Long
openaire   +2 more sources

Video Recording Paper - Innovation In Video Recording

SPIE Proceedings, 1984
Traditionally, multiple format recording emulsions for medical video imaging have utilized a film (transparent) base. The major reason for this is probably because the film and camera manufacturers felt the diagnostician is accustomed to viewing x-ray images on a film base and would prefer to view video images that way also. Because of the need to keep
openaire   +1 more source

Home - About - Disclaimer - Privacy