Results 241 to 250 of about 113,790 (365)

Evaluation of the glottic surface dose in three‐dimensional conformal radiotherapy for early‐stage glottic cancer using a treatment planning system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
ABSTRACT Background In radiotherapy for early‐stage glottic cancer, evaluating the target surface dose at the glottic air–tissue boundary is crucial, as buildup effect can cause underdosing. The accuracy of dose evaluation in the surrounding tissues is affected by both the dose calculation algorithms and the accuracy of the Hounsfield unit values in ...
Yuki Saito   +3 more
wiley   +1 more source

Assessing proton plans with three different beam delivery systems versus photon plans for head and neck tumors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To compare plan quality among photon volumetric modulated arc therapy (VMAT) and intensity‐modulated proton therapy (IMPT) with robustness using three different proton beam delivery systems with various spot size (σ) ranges: cyclotron‐generated proton beams (CPBs) (σ: 2.7–7.0 mm), linear accelerator proton beams (LPBs) (σ: 2.9–5.5 mm),
Tara Gray   +9 more
wiley   +1 more source

The effect of kV imaging dose on PTV and OAR planning constraints in lung SBRT using stereoscopic/monoscopic real‐time tumor‐monitoring system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Quantify the impact of additional imaging doses on clinical dose constraints during lung stereotactic body radiotherapy (SBRT) treatment utilizing stereoscopic/monoscopic real‐time tumor monitoring. Materials and Methods Thirty lung SBRT patients treated with the volumetric arc therapy technique were randomly selected from the ...
Ruwan Abeywardhana, Mike Sattarivand
wiley   +1 more source

Effects of plasma-activated water on germination ‎and initial seedling growth of wheat. [PDF]

open access: yesPLoS One
Asghari A   +6 more
europepmc   +1 more source

Effects of cardiac motion on dose distribution during stereotactic arrhythmia radioablation treatment: A simulation and phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Cardiac motion may degrade dose distribution during stereotactic arrhythmia radioablation using the CyberKnife system, a robotic radiosurgery system. This study evaluated the dose distribution changes using a self‐made cardiac dynamic platform that mimics cardiac motion. Methods The cardiac dynamic platform was operated with amplitudes
Takayuki Miyachi   +6 more
wiley   +1 more source

Factors influencing students' happiness, vitality, and self-esteem. [PDF]

open access: yesFront Psychol
Majauskiene D   +11 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy