Results 31 to 40 of about 4,893,219 (280)
Comparative Study Regarding the Design of a 3D Printed Hip Prosthesis
This work proposes the comparison of two models of 3D printed hip prostheses, using microscopic and chemical analysis, but also compression and bending testing. The comparison was made using a hip prosthesis designed in the Autodesk Inventor 2020 program
Silvia-Iuliana NECULA +3 more
doaj +1 more source
Application of MRI-based Finite Element Modeling and Analysis in Periacetabular Osteotomy
Periacetabular osteotomy (PAO) is a surgical procedure to correct acetabular orientation in developmental dysplasia of the hip (DDH). In this work, magnetic resonance imaging-based finite element models of hip joint were introduced to perform virtual ...
ZHOU Tianli +6 more
doaj +1 more source
Virtual reality hip arthroscopy simulator demonstrates sufficient face validity [PDF]
AbstractPurposeTo test the face validity of the hip diagnostics module of a virtual reality hip arthroscopy simulator.MethodsA total of 25 orthopaedic surgeons, 7 faculty members and 18 orthopaedic residents, performed diagnostic supine hip arthroscopies of a healthy virtual reality hip joint using a 70° arthroscope.
Bartlett, Jonathan D +2 more
openaire +2 more sources
Background Posterior wall acetabular fractures remain one of the most difficult fracture injuries to treat. Accurate assessment of fracture characteristics and appropriate preoperative surgical strategies are essential for excellent reduction. This paper
Jianan Chen +7 more
doaj +1 more source
Background The treatment of comminuted posterior wall acetabular fractures remains challenging due to the difficulty in understanding of fracture patterns and lack of appropriate preoperative planning process. Virtual preoperative planning procedures are
Yifan Zheng +7 more
doaj +1 more source
In virtual reality (VR), rotation gains scale the mapping between a user’s physical and virtual rotation, helping users explore larger virtual environments within limited tracked spaces.
Hugo Brument +3 more
doaj +1 more source
A Low-Inertia and High-Stiffness Cable-Driven Biped Robot: Design, Modeling, and Control
In this paper, a biped robot system for dynamic walking is presented. It has two 2-degree-of-freedom (DOF) lightweight legs and a 6-DOF hip. All the joint pulleys of the legs are driven by motors that are placed at the hip using steel cables.
Jun Tang +5 more
doaj +1 more source
Combined Management of Meniscus Root Tear and High Tibial Osteotomy: A Surgical Strategy Using 3‐Dimensional Printing [PDF]
Abstract Combining high tibial osteotomy with meniscal posterior root repair is technically challenging because of the limited metaphyseal bone stock, the proximity of the transtibial tunnel to the osteotomy site, and the risk of implant conflict or tibial fracture.
Sherafatvaziri A +6 more
europepmc +2 more sources
Advances in Sustainable and Wearable Textile Based Soft Robotics
This Review examines advances in wearable textile‐based soft robotics, focusing on sustainable materials, integrated sensing, and scalable actuation. It discusses manufacturing and system integration across healthcare, assistive robotics, prosthetics, and human–machine interfaces, and highlights key challenges in circular design, including life‐cycle ...
Zahir Abbas +6 more
wiley +1 more source
Tribocorrosion of total hip replacements [PDF]
The performance of metal-on-metal total hip replacements is largely determined by their propensity to degrade in vivo. Degradation occurs through the complex interactions between wear and corrosion (termed tribocorrosion) and leads to the production of ...
Hesketh, James Edward Tilston
core +5 more sources

