Results 71 to 80 of about 6,867,597 (165)

Supplemental Material - Imaging of hypodense gliotic lesions in photon counting computed tomography using virtual monoenergetic images

open access: yes
Supplemental Material for imaging of hypodense gliotic lesions in photon counting computed tomography using virtual monoenergetic images by Denise Schoenbeck, Alexander Sacha, Julius Henning Niehoff, Christoph Moenninghoff, Jan Borggrefe, Jan Robert ...
Jan Robert Kroeger (5316179)   +6 more
core   +1 more source

Comparison of three commercial multi‐energy CT and electron density phantoms for iodine quantification and tissue substitute characterization

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 8, August 2026.
Abstract Background Multi‐energy computed tomography (MECT) and electron density (ED) phantoms are designed for evaluating the performance of CT scanners. They include substitute materials representing the energy‐ and material‐dependent CT numbers of different organs, tissues, or contrast agents.
Artur Omar   +3 more
wiley   +1 more source

Dual-energy CT-based virtual monoenergetic imaging via unsupervised learning

open access: yesPhysical and Engineering Sciences in Medicine
Abstract Since its development, virtual monoenergetic imaging (VMI) derived from dual-energy computed tomography (DECT) has been shown to be valuable in many clinical applications. However, DECT-based VMI showed increased noise at low keV levels. In this study, we proposed an unsupervised learning method to generate VMI from DECT.
Chi-Kuang, Liu   +2 more
openaire   +2 more sources

A physics primer on photon‐counting detectors in CT: Physics, signal formation, and performance

open access: yesMedical Physics, Volume 53, Issue 8, August 2026.
Abstract Photon‐counting detector CT (PCD‐CT) is moving from laboratory development to clinical deployment. However, its threshold‐bin data arise from a tightly coupled detector–readout chain that can be difficult to understand as a whole. These data are not a direct readout of photon energy, but the outcome of a sequence of physical and electronic ...
Guang‐Hong Chen, Ruiran Lai, Ke Li
wiley   +1 more source

Peculiar Magnetosphere‐Atmosphere Coupling and Its Impacts Over the South American Magnetic Anomaly Region

open access: yesJournal of Geophysical Research: Space Physics, Volume 131, Issue 8, August 2026.
Abstract The auroral‐like sporadic E‐layer is typically observed at altitudes between 100 and 150 km within the South American Magnetic Anomaly region. However, the occurrence of an unusual layer event detected above this altitude range on 18 July 2017 has raised intriguing questions regarding the physical processes responsible for the substantial ...
Lígia A. Da Silva   +21 more
wiley   +1 more source

Potential of quantitative X‐ray imaging from photon‐counting CT: A novel analysis based on effective atomic number and physical density

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 7, July 2026.
Abstract Background Conventional CT assessment of lung lesions is based mainly on morphological features. CT values represent relative X‐ray attenuation that does not directly reflect tissue composition and/or physical density. Quantitative imaging using photon‐counting CT (PC‐CT) has the potential to provide quantitative parameters, such as effective ...
Takashi Asahara   +9 more
wiley   +1 more source

BasisSimulator.jl: Open-source polychromatic CT simulation with a GPU-portable reconstruction stack

open access: yesSoftwareX
BasisSimulator.jl is an open-source polychromatic computed tomography simulator written in Julia for virtual imaging trials. Five user-facing structs and two top-level calls define and execute a complete acquisition.
Dale Black   +2 more
doaj   +1 more source

Low tube voltage increases the diagnostic performance of dual-energy computed tomography in patients with acute appendicitis

open access: yesDiagnostic and Interventional Radiology, 2019
PURPOSEWe aimed to assess the utility of dual-energy computed tomography (DECT) imaging in diagnosing acute appendicitis (AA) with density measurements of the appendix vermiformis.METHODSA total of 210 consecutive patients presenting with acute abdominal
Çağdaş Topel   +5 more
doaj   +1 more source

Introduction to TREx‐ATM V2.0: A Versatile Model of Auroral Transport and Its Effects in the Ionosphere

open access: yesEarth and Space Science, Volume 13, Issue 7, July 2026.
Abstract Auroral transport models (ATMs) play an important role in quantitative studies of optical auroras, their driving mechanisms, and their effects on the ionosphere and thermosphere. TREx‐ATM was initially developed as the support model for the Transition Region Explorer (TREx) mission, and has gained increasing applications in the community in ...
Jun Liang   +5 more
wiley   +1 more source

Comparison of Low‐Iodine Concentration Quantification Accuracy and Contrast‐To‐Noise Ratio Across Three Dual‐Energy CT Techniques: A Phantom Study

open access: yesJournal of Medical Radiation Sciences, Volume 73, Issue 2, Page 224-232, June 2026.
Using a clinical abdominal CT protocol, all three DECT techniques accurately quantified iodine. Rapid kV‐switching achieved the lowest detectable and quantifiable iodine concentrations, while dual‐layer DECT provided the highest normalised contrast‐to‐noise ratio on 40‐keV virtual monoenergetic images.
Chonsitron Sirituenlee   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy