Results 1 to 10 of about 1,304,317 (156)
Virtual Implantation Technique to Estimate Endoprosthetic Contact of Percutaneous Osseointegrated Devices in the Tibia [PDF]
Percutaneous osseointegrated (OI) devices have an endoprosthesis attached to the residual bone of an amputated limb, then pass permanently through the skin to be connected to the distal prosthetic componentry outside of the body. Whether the bone-anchoring region of current OI endoprostheses are cylindrical, and/or conical, they require intimate bone ...
Carolyn E Taylor +2 more
exaly +4 more sources
To re-create a 3D parametrical environment it was used a CAD software which permits to define complex models. First, there were defined the main bone components as femur, tibia and pelvis by using the CT images. The contours of the CT images were transferred to CAD environment where, step by step, and section by section, the virtual bones were defined.
Cosmin Mihai Miriţoiu +2 more
exaly +3 more sources
Implications of the Overlapping Degree Between Proximal Fibula and Tibia for Placing the Optimal Syndesmotic Screw: A Virtual Cadaveric Study [PDF]
Abstract Background: To determine the optimal direction of the syndesmotic screw and introduce a consistent landmark for practical application by analyzing three-dimensional (3D) modeling and virtual implantation.Methods: A total of 102 cadaveric lower legs (50 males and 55 females, average height of 160.6 ± 7.1cm) were used to reconstruct a 3D
Gu-Hee Jung +4 more
openaire +4 more sources
Ashley Lamb,1 Brandon McKinney,1 Petros Frousiakis,1 Graal Diaz,2 Stephan Sweet1 1Orthopedic Surgery, Community Memorial Hospital, Ventura, CA, USA; 2Research Department-Graduate Medical Education, Community Memorial Healthcare System, Ventura, CA ...
Lamb A +4 more
doaj +2 more sources
Performance of μMRI‐Based virtual bone biopsy for structural and mechanical analysis at the distal tibia at 7T field strength [PDF]
AbstractPurposeTo assess the performance of a 3D fast spin echo (FSE) pulse sequence utilizing out‐of‐slab cancellation through phase alternation and micro‐magnetic resonance imaging (μMRI)‐based virtual bone biopsy processing methods to probe the serial reproducibility and sensitivity of structural and mechanical parameters of the distal tibia at 7.0T.
Yusuf A, Bhagat +7 more
openaire +3 more sources
Obtaining alignment during end-stage knee osteoarthritis with extraarticular deformities has always been challenging. Therefore, we report a case of total knee arthroplasty, following the application of Taylor Spatial Frame to treat knee osteoarthritis ...
Tsuneari Takahashi +2 more
doaj +2 more sources
Sex and stature estimation on the tibia: a virtual pilot study on a contemporary Hispanic population
Abstract Sex and stature estimation represent two pillars in the creation of the biological profile, providing crucial demographic information that forensic anthropologists use for the identification of unknown skeletonized remains. This pilot study evaluates population data proposing a virtual sex and stature estimation method for a ...
Mittino, Giorgia +2 more
openaire +3 more sources
Background Three-dimensional (3D) printing techniques have been used to produce anatomical models and surgical guiding instruments in orthopaedic surgery. The geometric accuracy of the 3D printed replica may affect surgical planning.
Chi-Pin Hsu +6 more
doaj +2 more sources
Abstract Objective. To obtain maps of absorbed dose and an estimate of the effective dose to an adult patient for a high resolution peripheral quantitative computed tomography (HR-pQCT) (XtremeCT II) examination of the distal tibia and radius, using a graphical processing unit (GPU)-based Monte Carlo (MC) code ...
Laura Antonia Cerbone +5 more
openaire +4 more sources
INTRODUCTION HR-pQCT based micro finite element (μFE) analyses are considered as "gold standard" for virtual biomechanical analyses of peripheral bone sites such as the distal segment of radius and tibia.
Philippe Zysset +2 more
exaly +2 more sources

