Results 181 to 190 of about 561 (262)
Seismic collapse capacity analysis of degrading SDOF systems with uncoupled negative and positive stiffness mechanism. [PDF]
Liu Y, Sun F, Xu D, Yang J.
europepmc +1 more source
Abstract This study investigates the numerical modeling of internal tendon breaks in prestressed concrete structures and evaluates the key parameters affecting accuracy. A combined approach is followed, involving global sensitivity analysis via the Elementary Effects Method and subsequent model calibration using experimental data from distributed fiber‐
Aeneas Paul, David Sanio, Peter Mark
wiley +1 more source
Acoustic scattering and mode interaction in bifurcated circular waveguide structures with reacting liners and discontinuities. [PDF]
Alkuhayli N +3 more
europepmc +1 more source
ABSTRACT The breathing system of an oil‐immersed transformer is of vital importance for maintaining equilibrium between internal and external pressures, with any malfunction potentially disrupting the transformer's stable operation. This study develops a thermal–fluid–structure interaction (TFSI) model to simulate the breathing phenomenon in a 110 kV ...
Lujia Wang +5 more
wiley +1 more source
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang +5 more
wiley +1 more source
800 kV Fast Circuit Breaker: Mechanical Coupling Modelling, Buffer Design and Development
ABSTRACT The 800 kV fast circuit breaker (CB) used in ultra‐high voltage (UHV) converter transformer can reduce the total breaking time to 25 ms. It significantly improves the action speed and breaking capacity of the CB, with promising broad application prospects.
Enyuan Dong +6 more
wiley +1 more source
Review of Catenary Icing on High‐Speed Railways: Characteristics, Impact and Countermeasures
ABSTRACT The pantograph–catenary system (PCS) is the only path for electrified railway trains to acquire energy. Catenary icing during winter is a common natural phenomenon, which usually leads to the deterioration of the current quality and severely affects the operational safety of trains.
Zheng Li +7 more
wiley +1 more source
Liquid jet capabilities for ultrafast chemistry at the SwissFEL Alvra instrument
The technical aspects of the Alvra endstation are outlined and its scientific capabilities are demonstrated with commissioning results obtained during the early years of SwissFEL's operation.The Alvra experimental station at the Swiss X‐ray free‐electron laser, SwissFEL, investigates ultrafast dynamics in chemical and biological systems using X‐ray ...
Claudio Cirelli +9 more
wiley +1 more source
Sensors and Sensing Devices Utilizing Electrorheological Fluids and Magnetorheological Materials-A Review. [PDF]
Park YJ, Choi SB.
europepmc +1 more source