Abstract In radiation oncology, inter‐fractional dosimetry using optically stimulated luminescent detectors (OSLDs) ensures accurate plan delivery and patient safety. RadPro International GmbH's myOLSchip system, featuring a beryllium oxide (BeO) OSL dosimeter, reader, and eraser, was characterized and calibrated with a Varian Truebeam for in‐vivo ...
Heath Davis+3 more
wiley +1 more source
Light-induced Electron-transfer Reactions. 5. Kinetics of the Oxidation of Ethylenediaminetetraacetatocobaltate(II) Complexes by Peroxodisulfate Ion, Induced by Irradiation with Visible Light of Aqueous Solutions Containing Tris(2,2′-bipyridine)ruthenium(II) Ion [PDF]
Suzuko Nishida, Mutsumi Kimura
openalex +1 more source
Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White+5 more
wiley +1 more source
Efficient Photoreduction of Methylviologen Sensitized by Chlorophyll Derivatives and Hydrogen Evolution by Visible Light [PDF]
Takashi Koiso+3 more
openalex +1 more source
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa+4 more
wiley +1 more source
Photooxidative Damage to Mammalian Cells and Proteins by Visible Light [PDF]
Lester Packer, E. W. Kellogg
openalex +1 more source
Visible Light Part I. Properties and Cutaneous Effects of Visible Light.
Evan Austin+6 more
semanticscholar +1 more source
Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda+9 more
wiley +1 more source
Automated rapidplan model validation using Eclipse scripting API
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma+2 more
wiley +1 more source
ABSTRACT Objective Increasing evidence shows that patients with intracerebral hemorrhage (ICH) can achieve better‐than‐expected outcomes with aggressive therapy. However, real‐world long‐term data, patient‐centered outcomes, and societal measures after maximal ICH treatment are lacking.
Anne Mrochen+11 more
wiley +1 more source