Evaluation of the system accuracy of frameless stereotactic radiosurgery using a combination of cone beam CT, six degrees of freedom couch, and surface image‐guided systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate the accuracy of the frameless linear accelerator‐based stereotactic radiosurgery (FSRS) system incorporating cone‐beam CT (CBCT), six degrees of freedom (6‐DoF) couch, room laser, and surface image‐guided (SG) systems.
Hao‐Wen Cheng   +4 more
wiley   +1 more source

Shielding resources for four common radiopharmaceuticals utilized for imaging and therapy: Tc‐99m, F‐18, I‐131, and Lu‐177

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction The use of radioactive materials in the United States has been tightly regulated by the Nuclear Regulatory Commission and other entities for many decades. In 2015, however, the Joint Commission began to require hospital‐based nuclear medicine departments to conduct shielding designs and evaluations for radioactive material areas ...
Michael Oumano   +12 more
wiley   +1 more source

Characterizing Visual Fields in RPGR Related Retinitis Pigmentosa Using Octopus Static-Automated Perimetry. [PDF]

open access: yesTransl Vis Sci Technol, 2022
Buckley TMW   +5 more
europepmc   +1 more source

Surface dose analysis and dosimetric comparison of Halcyon versus Truebeam in breast cancer radiotherapy: An OSL dosimetry study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Breast cancer is a neoplastic disease with high prevalence among women. Radiotherapy is one of the principal treatment modalities for this disease, but it poses significant challenges. This study aimed to compare and evaluate the technical and dosimetric performance of conventional C‐arm linac systems and a new design, Halcyon, in the ...
Mustafa Çağlar   +8 more
wiley   +1 more source

Reimagining Data Visualization to Address Sustainability Goals [PDF]

open access: yesarXiv
Information visualization holds significant potential to support sustainability goals such as environmental stewardship, and climate resilience by transforming complex data into accessible visual formats that enhance public understanding of complex climate change data and drive actionable insights.
arxiv  

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

Idiopathic Vitreopapillary Traction: Case Report and Literature Review

open access: yesCase Reports in Ophthalmology
Introduction: Vitreopapillary traction (VPT) syndrome occurs at the vitreopapillary interface. VPT can be idiopathic which indicates an abnormal or anomalous posterior vitreous detachment which present in elderly patients.
Hind Abdullah   +2 more
doaj   +1 more source