Results 111 to 120 of about 1,445 (233)

Magnetic properties of geraisites, the first tektite strewn field identified in Brazil

open access: yesMeteoritics &Planetary Science, EarlyView.
Abstract Geraisites are a newly recognized class of tektite from Brazil. They occur as centimeter‐sized, elongated to subspherical bodies scattered across surface gravel and shallow subsurface layers within a ~90‐km‐long strewn field extending between the municipalities of São João do Paraíso and Curral de Dentro, near the border between the states of ...
Melissa De Andrade Nunes   +7 more
wiley   +1 more source

Image_1_Rheological Properties and Age-Related Changes of the Human Vitreous Humor.TIF

open access: yes, 2018
The vitreous humor is a fragile, transparent hydrogel situated between the lens and the retina, occupying 80% of the eye's volume. Due to its viscoelastic behavior, the vitreous serves as a mechanical damper for the eye, absorbing impacts, and protecting
Katelyn E. Swindle-Reilly (6092546)   +1 more
core   +1 more source

Hyaluronic acid: A novel approach in regenerative/reconstructive periodontal therapy?

open access: yesPeriodontology 2000, EarlyView.
Abstract Background Although hyaluronic acid (HA) has long been used for many medical applications, only in recent years has it gained greater popularity in the field of periodontics because of its biological effects during wound healing. Even today, most clinicians are not aware that more than one type of HA exists and that the extent of its ...
Andrea Pilloni   +7 more
wiley   +1 more source

Desired properties of polymeric hydrogel vitreous substitute

open access: yesBiomedicine & Pharmacotherapy
Vitreous replacement is a commonly employed method for treating a range of ocular diseases, including posterior vitreous detachment, complex retinal detachment, diabetic retinopathy, macular hole, and ocular trauma. Various clinical substitutes for vitreous include air, expandable gas, silicone oil, heavy silicone oil, and balanced salt solution ...
Sheng Qu   +4 more
openaire   +2 more sources

An Injectable oxidated hyaluronic acid/adipic acid dihydrazide hydrogel as a vitreous substitute

open access: yes, 2011
[[abstract]]Vitrectomy is a common procedure for treating ocular-related diseases. The surgery involves removing the vitreous humor from the center of the eye, and vitreous substitutes are needed to replace the vitreous humor after vitrectomy.
Su, WY;Chen, KH;Chen, YC;Lee, YH;Tseng, CL;Lin, FH
core   +1 more source

Prevalence and outcome of lens capsule disruption in routine canine cataract surgery: A retrospective study of 520 eyes (2012–2019)

open access: yesVeterinary Ophthalmology, Volume 28, Issue 2, Page 141-149, March 2025.
Abstract Objective To investigate the prevalence and surgical outcome of lens capsule disruption (LCD) in dogs undergoing cataract removal. Animals studied Medical records of 924 eyes undergoing phacoemulsification were analyzed retrospectively. Procedures Routine cataract surgeries with or without LCD were included. Any LCD other than routine anterior
Amy L. M. M. Andrews   +2 more
wiley   +1 more source

Evaluation for endotoxin in intraocular materials used during phacoemulsification surgery using a recombinant factor C assay

open access: yesVeterinary Ophthalmology, Volume 28, Issue 2, Page 481-485, March 2025.
Abstract Objective Cataract surgery remains the sole method to resolve blindness secondary to cataract formation. One complication includes fibrin web formation post‐operatively. This study aimed to investigate the presence of endotoxin within materials used during cataract surgery as a possible cause of fibrin web phenomenon. Methods Preservative‐free
Taylor A. Opgenorth   +3 more
wiley   +1 more source

Vision outcomes in dogs with primary glaucoma surgically treated with lensectomy and endolaser cyclophotocoagulation after an Ahmed valve gonioimplantation failure

open access: yesVeterinary Ophthalmology, Volume 28, Issue 2, Page 207-217, March 2025.
Abstract Objective The aim of this study was to retrospectively evaluate vision outcomes of dogs with primary angle closure glaucoma (PACG) that underwent Ahmed valve gonioimplantation (AVG) followed by lensectomy and endolaser cyclophotocoagulation (ECP) with or without bleb resection after AVG failure.
Bactelius Turicea   +3 more
wiley   +1 more source

Rheology of vitreous humour and pharmacological substitutes used in eye surgery

open access: yes, 2015
The Vitreous Humour (VH) is a transparent gel that fills the vitreous cavity in the Human eye. VH is mainly composed of water (99%) and includes a network of protein fibrils (collagen) and hyaluronan (1%).
Oliveira, M.S.N.   +2 more
core  

Home - About - Disclaimer - Privacy