Results 191 to 200 of about 29,307 (243)
Some of the next articles are maybe not open access.
Fully automated segmentally boosted VMAT
Medical Physics, 2023AbstractPurposeTreatment planning for volumetric modulated arc therapy (VMAT) typically involves the use of multiple arcs to achieve sufficient intensity modulation. Alternatively, we can perform segment boosting to achieve similar intensity modulation while also reducing the number of control points used. Here, we propose the MetaPlanner Boosted VMAT (
Charles, Huang +3 more
openaire +2 more sources
Biomedical Physics & Engineering Express, 2022
Abstract Objective. Feasibility of three-dimensional (3D) tracking of volumetric modulated arc therapy (VMAT) based on VMAT–computed tomography (VMAT-CT) has been shown previously by our group.
Xiaodong Zhao, Rui Zhang
openaire +2 more sources
Abstract Objective. Feasibility of three-dimensional (3D) tracking of volumetric modulated arc therapy (VMAT) based on VMAT–computed tomography (VMAT-CT) has been shown previously by our group.
Xiaodong Zhao, Rui Zhang
openaire +2 more sources
4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung
Physics in Medicine and Biology, 2013Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process.
E, Chin, S K, Loewen, A, Nichol, K, Otto
openaire +2 more sources
Coplanar VMAT vs. noncoplanar VMAT in the treatment of sinonasal cancer
Strahlentherapie und Onkologie, 2014Previous studies showed that noncoplanar intensity-modulated radiotherapy (NC-IMRT) for sinonasal cancer is superior to coplanar intensity-modulated radiotherapy (IMRT). Volumetric-modulated arc therapy (VMAT) is a newly introduced treatment modality, and the performance of noncoplanar VMAT for sinonasal cancer has not been well described to date.To ...
Ning, Zhong-Hua +10 more
openaire +2 more sources
Sci-Thur PM: YIS - 03: Comparing 4D-VMAT, Gated-VMAT and 3D-VMAT in SBRT treatment of lung cancer
Medical Physics, 2012To evaluate the treatment plan qualities of 4D-VMAT, gated-VMAT and 3D-VMAT in the treatment of non-small cell lung cancer (NSCLC) in stereotactic body radiation therapy (SBRT).4D-VMAT is a motion compensation strategy that aims to exploit relative target and OAR motion to increase OAR sparing over 3D-VMAT without the long treatment times associated ...
E, Chin, S, Loewen, A, Nichol, K, Otto
openaire +4 more sources
Medical Dosimetry, 2020
This is the first study that compared treatment plan quality and planning efficiency for lung stereotactic body radiation therapy (SBRT) using CyberKnife (CK) Multiplan vs Varian Eclipse treatment planning systems, including volumetric modulated arc therapy (VMAT) and knowledge-based VMAT (KBP-VMAT). Thirteen lung SBRT patients treated with 50 to 55 Gy
Suhong, Yu +5 more
openaire +2 more sources
This is the first study that compared treatment plan quality and planning efficiency for lung stereotactic body radiation therapy (SBRT) using CyberKnife (CK) Multiplan vs Varian Eclipse treatment planning systems, including volumetric modulated arc therapy (VMAT) and knowledge-based VMAT (KBP-VMAT). Thirteen lung SBRT patients treated with 50 to 55 Gy
Suhong, Yu +5 more
openaire +2 more sources
Dose rate mapping of VMAT treatments
Physics in Medicine and Biology, 2016Human tissues exhibit a varying response to radiation dose depending on the dose rate and fractionation scheme used. Dose rate effects have been reported for different radiations, and tissue types. The literature indicates that there is not a significant difference in response for low-LET radiation when using dose rates between 1 Gy min(-1) and 12 Gy ...
Podesta, Mark +2 more
openaire +3 more sources
Online adaptation and verification of VMAT
Medical Physics, 2015Purpose:This work presents a method for fast volumetric modulated arc therapy (VMAT) adaptation in response to interfraction anatomical variations. Additionally, plan parameters extracted from the adapted plans are used to verify the quality of these plans.
Wouter, Crijns +6 more
openaire +2 more sources

