Purpose: The purpose of the present study was first to apply the progressive optimization algorithm based automatic volumetric modulated arc therapy (POA-VMAT) technology to accelerate and improve the radiotherapy of cervicothoracic esophageal cancer ...
Yongqiang Zhou MS +3 more
doaj +1 more source
Abstract Background Accurate heterogeneity correction in high‐precision radiotherapy relies on precise computed tomography (CT) number‐to‐density conversion via the Hounsfield unit look‐up table (HLUT). While physical properties of tissue‐equivalent materials are generally assumed consistent with manufacturer specifications, an independent audit ...
Minoru Nakao +5 more
wiley +1 more source
Stereotactic body radiation therapy (SBRT) given in 1-5 fractions is an effective treatment for vertebral metastases. Real-time magnetic resonance-guided radiotherapy (MRgRT) improves soft tissue contrast, which translates into accurate delivery of spine
Yadav Poonam +5 more
doaj +1 more source
Abstract Background Variability in low monitor unit (MU) deliveries has been previously documented, but the underlying pulse‑level behavior has not been fully described due to the integrating nature of most conventional detectors. A plastic scintillation detector (PSD) enables direct visualization of MU microstructure by isolating individual linac ...
Andrew J. White +3 more
wiley +1 more source
Dual‐scan conformal cone‐beam CT for targeted image‐quality improvement using dynamic collimation
Abstract Background Cone‐beam computed tomography (CBCT) is routinely used for image guidance in radiation therapy, but conventional full‐field CBCT acquisition may expose anatomically irrelevant regions and generate substantial scatter, which degrades soft‐tissue contrast and limits the accuracy of target localization and adaptive radiotherapy ...
Yuxiang Liu +3 more
wiley +1 more source
Abstract Background and purpose Anatomical changes during radiotherapy for nasopharyngeal carcinoma (NPC) frequently compromise target volume coverage while escalating dose delivery to organs at risk (OARs). In adaptive radiotherapy (ART), optimizing workflow efficiency to minimize clinical workload while maximizing patient benefit remains a ...
Zhenmei Cao +8 more
wiley +1 more source
Purpose: To evaluate the dosimetric and delivery performance of Elekta high-definition dynamic radiosurgery (HDRS) in hypofractionated stereotactic radiotherapy (HSRT) for multiple brain metastases (BMs) by comparison with a conventional single-isocenter
Jialu Lai, An Li, Jia Liu, Lin Zhou
doaj +1 more source
Abstract BackgroundWhile positioning errors during radiotherapy are increasingly well‐characterized and accounted for in the Planning Target Volume (PTV), little is known about the shape and volume changes of the breast in the course of radiotherapy. Yet they represent an unknown factor that may impact treatment effectiveness, highlighting the need to ...
Pierre Galmiche +5 more
wiley +1 more source
Yucel Saglam,1,2 Yasemin Bolukbasi,1– 3 Ali Ihsan Atasoy,1 Fatih Karakose,1 Mustafa Budak,1 Vildan Alpan,1,2 Erkan Topkan,4 Ugur Selek1– 3 1Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, Turkey; 2UT MD Anderson Radiation ...
Saglam Y +7 more
doaj
Background: Despite of the use of tangential beam directions during the irradiation of mammary carcinomas, a dose reduction of the heart cannot always be achieved.
Wagner Linda, Koch Thomas, Fahrig Antje
doaj +1 more source