Results 31 to 40 of about 21,069 (164)

Locking Plate for AO Type C Intra-articular Distal Radius Fracture: Volar or Dorsal Approach?

open access: yesJournal of Orthopaedics, Trauma and Rehabilitation, 2014
Purpose: There is controversy over the outcomes and complications of volar and dorsal plating for the treatment of intra-articular fracture distal radius.
Ka-Ho Tsang   +4 more
doaj   +1 more source

Expanded Utilization of the Digital Atasoy Flap

open access: yesPlastic and Reconstructive Surgery, Global Open, 2018
Background:. The Atasoy, or Kleinert flap, is well-known to hand surgeons. This triangular volar V-Y flap is frequently used for reconstruction of fingertip amputations with exposed bone.
Enrique J. Viciana, MD   +1 more
doaj   +1 more source

A Novel Surgical Technique for Neglected Volar Dislocation of the Lunate: Cases Report and Literature Review

open access: yesOrthopaedic Surgery, 2023
Background Treatments for chronic perilunate or lunate dislocations are very difficult and associated with poor prognoses. There is no established treatment method and are still many controversies.
Soo‐Hwan Kang   +7 more
doaj   +1 more source

Volar Dislocation of the Metacarpophalangeal Joint of the Ring Finger Complicated with Chondrolysis: A Case Report and Review of the Literature

open access: yesJournal of Orthopaedics, Trauma and Rehabilitation, 2017
Volar dislocation of the metacarpophalangeal joint is rare injury. In the literature consulted only seven cases of isolated volar dislocation of the metacarpophalangeal joint of the ring finger have been published.
Kam Keung Lai, Yuen Fai Leung
doaj   +1 more source

Anatomic Risks with Overpenetration of the Volar Locking Plates' Proximal Holes [PDF]

open access: green, 2023
Daniel Y. Hong   +4 more
openalex   +1 more source

Comparison of Dorsal and Volar Percutaneous Approaches in Acute Scaphoid Fractures: A Meta-Analysis. [PDF]

open access: yesPLoS ONE, 2016
The dorsal approach allows better central screw placement along the long axis of the scaphoid compared with the volar approach in managing acute scaphoid fractures. However, it is unclear whether the dorsal approach leads to better clinical outcomes than
Kyu-Bok Kang   +3 more
doaj   +1 more source

Assessment of Radiological Outcomes of Extra-articular Distal End Radius Fractures Treated by Volar Locking Plating versus Percutaneous K-wire and Cast Application: A Retrospective Observational Study

open access: yesJournal of Clinical and Diagnostic Research
Introduction: Extra-articular distal end radius fractures are among the most commonly encountered orthopedic injuries. Closed reduction with percutaneous K-wiring and cast application is a widely used method of treatment due to its minimally invasive ...
Jaiwardhan Prithviraj Bhosale   +2 more
doaj   +1 more source

Modified Arthroscopic Volar Scapholunate Capsuloligamentous Repair in Chronic Severe but Reducible Volar Scapholunate Instability

open access: yesArthroscopy Techniques
The scapholunate complex is composed of the intrinsic scapholunate ligament and the surrounding extrinsic ligamentous system on the dorsal and volar sides of the wrist.
Chul Ki Goorens, M.D.   +1 more
doaj   +1 more source

Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study

open access: yesJournal of Orthopaedics and Traumatology, 2019
Background Plate protrusion is a risk factor for flexor pollicis longus (FPL) rupture following volar locking plate (VLP) surgery. However, plate prominence on follow-up radiographs is common. We hypothesised that a VLP that does not touch the FPL tendon
Kotaro Sato   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy