Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review [PDF]
To position the volar plate on the distal radius fracture site, the pronator quadratus muscle needs to be detached from its distal and radial side and lifted for optimal exposure to the fracture site. Although the conventional approach involves repair of
Bos, F.J.M.E. (Fernande J.M.E.) +4 more
core +10 more sources
Objective: The purpose of this study was to document a new complication in volar locking plating of the distal radius. Methods: Between January 2007 and January 2014, 223 patients were identified from the department’s surgical database with ...
Tahir Sadik Sugun +5 more
doaj +1 more source
Cost effectiveness of treatment with percutaneous Kirschner wires versus volar locking plate for adult patients with a dorsally displaced fracture of the distal radius: Analysis from the DRAFFT trial [PDF]
We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with ...
Achten, J +6 more
core +1 more source
Purpose: Unstable distal radius intra-articular fractures require restoration of alignment. Exact fixation of intra-articular fragments is ideal. Here, we employed intraoperative computed tomography (CT) navigation to insert screws accurately in the ...
Akira Kawabata, MD +3 more
doaj +1 more source
Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes [PDF]
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures.
Farooque, K. +3 more
core +1 more source
Background Multiple approaches for fixation of distal radius fractures exist; nonetheless, there is no consensus on the optimal treatment for these injuries.
Feng-Shuo Chang +4 more
doaj +1 more source
Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures [PDF]
Objectives: To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type. Methods: A total of 136 patients who received either a 2.4 mm (n
Audigé, L. +6 more
core +1 more source
Background: Distal end-of-radius fractures are one of the most common fractures seen worldwide, accounting for approximately one-sixth of all fractures.
K M Pawan Kumar +2 more
doaj +1 more source
A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases [PDF]
BACKGROUND: Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials,
Adani, Roberto +4 more
core +1 more source
Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures [PDF]
Background: Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the ...
Florian Gras, M. +6 more
core +1 more source