Results 31 to 40 of about 4,406 (256)

Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review [PDF]

open access: yes, 2017
To position the volar plate on the distal radius fracture site, the pronator quadratus muscle needs to be detached from its distal and radial side and lifted for optimal exposure to the fracture site. Although the conventional approach involves repair of
Bos, F.J.M.E. (Fernande J.M.E.)   +4 more
core   +10 more sources

A new complication in volar locking plating of the distal radius: longitudinal fractures of the near cortex

open access: yesActa Orthopaedica et Traumatologica Turcica, 2020
Objective: The purpose of this study was to document a new complication in volar locking plating of the distal radius. Methods: Between January 2007 and January 2014, 223 patients were identified from the department’s surgical database with ...
Tahir Sadik Sugun   +5 more
doaj   +1 more source

Cost effectiveness of treatment with percutaneous Kirschner wires versus volar locking plate for adult patients with a dorsally displaced fracture of the distal radius: Analysis from the DRAFFT trial [PDF]

open access: yes, 2015
We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with ...
Achten, J   +6 more
core   +1 more source

Volar Locking Plate Fixation for Distal Radius Fractures by Intraoperative Computed Tomographic–Guided Navigation

open access: yesJournal of Hand Surgery Global Online, 2020
Purpose: Unstable distal radius intra-articular fractures require restoration of alignment. Exact fixation of intra-articular fragments is ideal. Here, we employed intraoperative computed tomography (CT) navigation to insert screws accurately in the ...
Akira Kawabata, MD   +3 more
doaj   +1 more source

Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes [PDF]

open access: yes, 2016
Background: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures.
Farooque, K.   +3 more
core   +1 more source

Evaluating the necessity of bone augmentation for distal radius fracture fixed with a volar locking plate: a retrospective study

open access: yesBMC Musculoskeletal Disorders, 2020
Background Multiple approaches for fixation of distal radius fractures exist; nonetheless, there is no consensus on the optimal treatment for these injuries.
Feng-Shuo Chang   +4 more
doaj   +1 more source

Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures [PDF]

open access: yes, 2013
Objectives: To investigate the differences of open reduction and internal fixation (ORIF) of complex AO Type C distal radius fractures between two different models of a single implant type. Methods: A total of 136 patients who received either a 2.4 mm (n
Audigé, L.   +6 more
core   +1 more source

Functional outcome of volar variable angle locking compression plate in distal end radius fractures: A retrospective case record analysis

open access: yesJournal of Orthopaedic Diseases and Traumatology, 2023
Background: Distal end-of-radius fractures are one of the most common fractures seen worldwide, accounting for approximately one-sixth of all fractures.
K M Pawan Kumar   +2 more
doaj   +1 more source

A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases [PDF]

open access: yes, 2014
BACKGROUND: Implants based on the polyetheretherketon (PEEK) polymer have been developed in the last decade as an alternative to conventional metallic devices. PEEK devices may provide several advantages over the use of conventional orthopedic materials,
Adani, Roberto   +4 more
core   +1 more source

Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures [PDF]

open access: yes, 2015
Background: Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the ...
Florian Gras, M.   +6 more
core   +1 more source

Home - About - Disclaimer - Privacy