Results 21 to 30 of about 1,622 (254)
Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report
Background Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. Case Presentation A 40 year-old, obese female patient who presented with
Ozer Kagan, Cao Jue
doaj +1 more source
Objective: The purpose of this study was to document a new complication in volar locking plating of the distal radius. Methods: Between January 2007 and January 2014, 223 patients were identified from the department’s surgical database with ...
Tahir Sadik Sugun +5 more
doaj +1 more source
Background: The aim of this study was to introduce and to evaluate the functional results of volar plating of distal radial fractures through a longitudinal minimally invasive approach. Methods: From January 2010 to January 2013, 157 patients with distal
Xu Zhang +5 more
doaj +1 more source
Introduction: The purpose of the present study was to compare the results obtained by management of intra-articular fractures of distal end radius with closed reduction and external fixation versus open reduction and internal fixation with locking distal
S.P.S Gill +5 more
doaj +1 more source
PurposesThe aim of this study was to compare clinical outcomes of dual-plate fixation and volar locking plate fixation in high-energy intra-articular distal radius fractures.MethodsIn this study, 168 patients with high-energy intra-articular distal ...
Lingyao Zhou +10 more
doaj +1 more source
Biologic plating of unstable distal radial fractures
Background Volar locking plating through the flexor carpi radialis is a well-established technique for treating unstable distal radial fractures, with few reported complications.
Jae-Man Kwak, Gu-Hee Jung
doaj +1 more source
Volar Plating vs. External Fixator with Cross K-wire for Distal Radius Fracture: A Comparative Study
Background: Now a days there is increased utilization of volar locking plates fixation over external fixation. However, the comparative complications and outcomes of both surgical methods are still unclear.
Saurabh Agarwal +3 more
doaj +1 more source
Plating the radial shaft on the lateral surface: An outcome study
Purpose: Plate fixation is the gold standard for the treatment of displaced forearm shaft fractures in adults. Conventionally radial shaft fractures will be plated either on the volar surface or on the dorsal surface depending on which approach has been ...
Muhammad Haseeb +4 more
doaj +1 more source
Adolescent Volar Barton Fracture with Open Physis treated with Volar Plating using Buttressing Principle [PDF]
Objective: The objective of the study was to assess the outcome of Salter- Harris type III distal radius fracture fixed using the principle of buttressing and avoiding screw insertion through the physis.
Shah H, Chavali V, Daveshwar R
doaj +1 more source
Functional outcome of distal radius fractures, an implant based approach - Narrative review
Objectives: To review the literature regarding the outcomes of the comparison of the surgical options for fixing the distal radius. To briefly document how surgical costs, operating times and complication rates may impact on the implant choice.
Cary Fletcher
doaj +1 more source

