Results 1 to 10 of about 2,776 (262)
Active arc suppression device based on voltage‐source convertor with consideration of line impedance in distribution networks [PDF]
Abstract In the non‐effectively grounding distribution system, residual current under single‐line‐to‐ground (SLG) fault threatens the safety of human being and power supply equipment. Active arc suppression device has been proved to be effective for SLG fault arc suppression when the line impedance is ignored.
Bishuang Fan +6 more
openaire +3 more sources
Mitigating Balanced and Unbalanced Voltage Sag Via Shunt-Connected Voltage Source Convertor (VSC) by using Double Vector Controller [PDF]
This study presents a shunt-Connected Voltage Source Convertor (VSC) to mitigate balanced and unbalanced voltage sag and regulate the grid voltage at a fixed level by inserting required reactive power at the Point of Common Coupling (PCC).Moreover, an inner Vector Current-Controller (VCC) and outer voltage controller (VVC) are applied together to ...
Abdollah Shokri +3 more
openaire +2 more sources
Hard- and software of real time simulation tools of Electric Power System for adequate modeling power semiconductors in voltage source convertor based HVDC and FACTS [PDF]
The motivation of the presented research is based on the needs for development of new methods and tools for adequate simulation of Flexible Alternating Current Transmission System (FACTS) devices and High Voltage Direct Current Transmission (HVDC) system as part of real electric power systems (EPS).
Ufa Ruslan A. +2 more
openaire +3 more sources
Multilevel Convertors for Distributed Power Generation Systems with DC Voltage Sources.
The paper is related to the problem of generating the high qual-ity AC voltage waveforms in distributed power generating systems with DC voltage sources like photo-voltaic farms and fuel cells. A novel approach to the synthesis of AC voltage waveforms, applying chosen analytical methods like Fourier transform, Haar ...
null A. Jan Iwaszkiewicz +1 more
openaire +2 more sources
Inverter's performance and operating mode may be negatively affected by inverter input (dc‐link) current and voltage ripple. It is a common experience that even theoretically balanced loads with perfectly balanced supply voltages, such as multiphase ac ...
Marija Vujacic +3 more
doaj +1 more source
For high‐power converters, the low switching frequency (SF) modulation represented by selective harmonic elimination pulse width modulation (SHE‐PWM) is crucial to reduce the switching loss and enhance the efficiency with a good steady‐state performance.
Bo Guan, Xuyang Yan
doaj +1 more source
Fast and fault‐tolerant model predictive control of MMCs under selective harmonic elimination
Selective harmonic elimination (SHE) is a suitable pulse‐width modulation (PWM) technique for some applications of modular multilevel converters (MMC) with lower number of semiconductor submodules (SM).
Ardavan Mohammadhassani +1 more
doaj +1 more source
It is very important to obtain high reliability in the high‐voltage direct current (HVDC) system operation because of extremely high and huge power capacity.
Chi‐Hwan Bae +2 more
doaj +1 more source
Considering that the AC–DC hybrid microgrid (HMG) is connected to the low‐voltage distribution network (DN) where voltage faults occur most commonly, the fault ride‐through (FRT) capability and power quality performance of the HMG under abnormal DN ...
Yi Du, Huadong Sun, Chao Zheng
doaj +1 more source
This paper presents a comprehensive assessment for the small‐signal voltage stability of voltage source converter (VSC)‐HVDC systems supplying industrial loads represented by the induction motors (IMs) and provides a stability enhancement control for the
Yicheng Xue +5 more
doaj +1 more source

