Results 101 to 110 of about 10,371,958 (212)

Low‐Voltage Pulsed GMA‐AM Application for Controlling Heat Input and Improving Deposition Quality of 309LSi Multilayered Structures

open access: yessteel research international, EarlyView.
This manuscript presents a study on the effects of parameter control of low‐voltage pulsed‐GMA‐AM application for producing 309LSi multilayered build‐ups, which can simultaneously lead to reduced heat input up to 32.1%, enable pulsed‐spray transfer, provide stable depositing conditions and preserve dimensional consistency, favoring fabrication of a 114‐
Petrônio L. C. C. C. Fernandes   +4 more
wiley   +1 more source

Serviceability reserves of historic reinforced concrete slabs implications for structural reuse

open access: yesStructural Concrete, EarlyView.
Abstract The transition to a circular economy in the construction sector requires reliable methods to assess whether existing reinforced concrete elements can be reused in new load‐bearing structures. A central question is whether slabs designed according to historical standards also meet today's serviceability requirements.
Robin Mecka   +2 more
wiley   +1 more source

Quantifying the embodied‐carbon premium of RC transfer beams via automated design

open access: yesStructural Concrete, EarlyView.
Abstract Transfer structures in reinforced concrete (RC) buildings enable architectural flexibility but often increase material use and embodied carbon. This study introduces an automated framework to quantify the embodied‐carbon premium associated with such systems. For each parametric configuration, two equivalent RC frames—one regular and one with a
Enrico Pinelli, David M. Ruggiero
wiley   +1 more source

Active Power Control of Full‐Scale Converter‐Based Wind Turbine Considering Turbine Angular Velocity for Short‐Term Frequency Stability in Power Systems

open access: yesIEEJ Transactions on Electrical and Electronic Engineering, EarlyView.
The increasing deployment of wind turbine generators (WTs) may alter the frequency stability of power systems. Unlike traditional synchronous generators, WTs are connected to the power system through converters. Consequently, WTs cannot provide an inertia response to the power system. Nevertheless, the converters can perform rapid control.
Seonghoen Oh, Kenichi Kawabe
wiley   +1 more source

Multi-terminal HVDC voltage droop control design considering DC grid, AC grid and MMC dynamics

open access: yes, 2017
In this paper, a voltage droop control tuning strategy for a four-terminal high-voltage direct current (HVDC) grid is described, considering the DC multi-terminal grid, the AC grid and the modular multilevel converter (MMC)
Gomis Bellmunt, Oriol   +2 more
core  

Modification and expansion of existing body condition scoring scales for rabbits (Oryctolagus cuniculus) improves inter‐rater reliability when used by experienced raters

open access: yesVeterinary Record, EarlyView.
Abstract Background Reliable body condition scoring in rabbits is essential in managing healthy bodyweight. The commonly used Rabbit size‐o‐meter (RSOM) has shown poor inter‐rater reliability, particularly among inexperienced raters. This study aimed to develop a reliable, reproducible body condition scoring scale for companion rabbits across breeds ...
Mette L. Halck   +6 more
wiley   +1 more source

Energy Flows Balance of Electric‐Heating Interconnected Microgrids Under Grid‐Forming Converter Integration Based on Heterogeneous Graph Convolutional Network

open access: yesEnergy Internet, EarlyView.
ABSTRACT The combination of electric‐heating interconnected microgrids (EHIMs) with grid‐forming converters (GFMCs) offers a highly promising approach to improving energy management within decentralised energy systems. Despite its potential, precisely modelling and analysing energy flow in such systems remains a considerable challenge due to the ...
Ji Li   +15 more
wiley   +1 more source

Mechanism of Quasi‐Power‐Frequency Resonant Overvoltage Triggered by Multiple Lightning Strikes in High‐Voltage Alternating Current Systems Equipped With Shunt Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang   +7 more
wiley   +1 more source

Local Search and the Evolution of World Models

open access: yesTopics in Cognitive Science, EarlyView., 2023
Abstract An open question regarding how people develop their models of the world is how new candidates are generated for consideration out of infinitely many possibilities. We discuss the role that evolutionary mechanisms play in this process. Specifically, we argue that when it comes to developing a global world model, innovation is necessarily ...
Neil R. Bramley   +3 more
wiley   +1 more source

Voltage stability improvement of weak grids using a new cascade droop control of grid-connected converter

open access: yes
The voltage control loop of a virtual synchronous generator (VSG) is typically governed by a conventional reactive power-voltage droop control, which may exhibit instability when encountering disturbances or operating under weak grid conditions.
Qobad Shafiee   +2 more
core   +1 more source