Results 41 to 50 of about 11,650 (204)

Directional derivative-based method for quasi-stationary voltage support analysis of single-infeed VSC-HVDC units

open access: yesHigh Voltage, 2020
This study presents an investigation of the impact of the quasi-stationary voltage support provided by a voltage source converter (VSC) connected to a single point of a power system.
Arcadio Perilla   +9 more
doaj   +1 more source

Reactive power sensitivity-based novel overvoltage suppression strategy for parallel VSC-and-LCC-HVDC transmission system

open access: yesInternational Journal of Electrical Power & Energy Systems
The rapid deployment of both line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage source converter-based high-voltage direct current (VSC-HVDC) does not only prolificate AC/DC grid coupling but also form new DC transmission ...
Yi Hao   +4 more
doaj   +1 more source

A Virtual Impedance Control Strategy for Improving the Stability and Dynamic Performance of VSC–HVDC Operation in Bidirectional Power Flow Mode

open access: yesApplied Sciences, 2019
It is a common practice that one converter controls DC voltage and the other controls power in two-terminal voltage source converter (VSC)−based high voltage DC (HVDC) systems for AC gird interconnection.
Yuye Li   +4 more
doaj   +1 more source

Sub-parts Control Parameter Fitting Method of VSC Based on RTDS

open access: yes发电技术, 2020
Voltage source converter (VSC) is the main power electronic components of wind power, photovoltaic and converter stations. It's control mode and parameter setting have important influence on system operation.
Peng XU   +3 more
doaj   +1 more source

Multi-terminal HVDC grids with inertia mimicry capability [PDF]

open access: yes, 2016
The high-voltage multi-terminal dc (MTDC) systems are foreseen to experience an important development in the next years. Currently, they have appeared to be a prevailing technical and economical solution for harvesting offshore wind energy. In this study,
Gharehpetian, Gevorg B.   +4 more
core   +2 more sources

Analysis of harmonics in subsea power transmission cables used in VSC-HVDC transmission systems operating under steady-state conditions [PDF]

open access: yes, 2007
Subsea power cables are a critical component of a voltage-source converter-high-voltage direct current (VSC-HVDC) transmission system in any offshore electrical power scheme.
Bucknall, R.W.G., Chien, C.H.
core  

Power hardware in the loop validation of fault ride through of VSC HVDC connected offshore wind power plants

open access: yesJournal of Modern Power Systems and Clean Energy, 2014
This paper presents the power hardware in the loop (PHIL) validation of a feed forward DC voltage control scheme for the fault ride through (FRT) of voltage source converter (VSC) high voltage DC (HVDC) connected offshore wind power plants (WPPs). In the
Ranjan Sharma   +5 more
doaj   +1 more source

Implementasi Hysterisis Current Control Pulse Witdh Modulation (HCCPWM) Untuk Inverter 3 Fasa

open access: yesJurnal Teknik Elektro Indonesia, 2021
Based on the source used, there are several types of converters, one of which is a voltage source converter (VSC). In this study, using a converter that can work as an inverter.
Tri Yogi Putra, Muldi Yuhendri
doaj   +1 more source

Stability Analysis in Multi-VSC (Voltage Source Converter) Systems of Wind Turbines [PDF]

open access: yesApplied Sciences
In this paper, a holistic nonlinear state-space model of a system with multiple converters is developed, where the converters correspond to the wind turbines in a wind farm and are equipped with grid-following control. A novel generalized methodology is developed, based on the number of the system’s converters, to compute the equilibrium points around ...
Dimitrios Dimitropoulos   +2 more
openaire   +2 more sources

Active distribution power system with multi-terminal DC links [PDF]

open access: yes, 2015
A fast power restoration operational scheme and relevant stabilizing control is proposed for active distribution power systems with multi-terminal DC network in replacement of the conventional normal open switches. A 9-feeder benchmark distribution power
Chen, Dong, Xu, Lie, Zhang, Wendian
core   +2 more sources

Home - About - Disclaimer - Privacy