Results 31 to 40 of about 69,905 (289)

Overview of Research Status of DC Bias and Its Suppression in Power Transformers

open access: yesEnergies, 2022
In this article, the sources of DC bias and its effects on power transformers are first summarized. Secondly, the article classifies and summarizes the current DC bias calculation problems of power transformers, and puts forward some interesting ...
Youliang Sun   +3 more
doaj   +1 more source

Optimal passive filter design for effective utilization of cables and transformers under non-sinusoidal conditions [PDF]

open access: yes, 2014
Transformers and cables have overheating and reduced loading capabilities under non-sinusoidal conditions due to the fact that their losses increases with not only rms value but also frequency of the load current.
Aleem, SHEA   +3 more
core   +1 more source

Less-conventional low-consumption galvanic separated MOSFET-IGBT gate drive supply [PDF]

open access: yes, 2017
A simple half-bridge, galvanic separated power supply which can be short circuit proof is proposed for gate driver local supplies. The supply is made while hacking a common mode type filter as a transformer, as the transformer shows a good insulation, it
Bikorimana, Jean Marie Vianney   +1 more
core   +3 more sources

Voltage distribution in multi‐cascaded transformer

open access: yesElectrical Engineering in Japan, 1997
The voltage distribution for lightning surges in multicascaded transformers that will be used for converter transformers in self-excited dc transmission was studied using model transformers. There was good agreement between measured data and calculated results.
Tatsuhito Nakajima   +4 more
openaire   +2 more sources

Optimal Operation of Distribution Electronic Power Transformer Using Linear Quadratic Regulator Method [PDF]

open access: yesJournal of Intelligent Procedures in Electrical Technology, 2011
Transformers perform many functions such as voltage transformation, isolation and noise decoupling. They are indispensable components in electric power distribution system.
Mohammad Hosein Rezaei   +2 more
doaj  

A Dimension Reduction Method Used in Detecting Errors of Distribution Transformer Connectivity

open access: yesIEEE Access, 2020
Many power utilities may have problems with the quality of data in records about which feeder a distribution transformer is connected to. This affects the operation and maintenance of smart grid infrastructure, outage management, line loss management ...
Zeyang Tang   +6 more
doaj   +1 more source

Voltage regulation considerations for the design of hybrid distribution transformers [PDF]

open access: yes, 2014
The future substation depends on finding a way to mitigate the effects of the drawbacks of the conventional legacy by employing the efficiency of the solid state switches [1].
Alqarni, M, Darwish, M, Radi, MA
core   +1 more source

Harmonic voltage measurement error of the capacitor voltage transformer

open access: yesPLOS ONE, 2018
This paper explores the mechanism for the harmonic voltage measurement error (HVME) of a capacitor voltage transformer (CVT) in a comprehensive way and develops a practical error correction method to improve the harmonic measurement performance of a CVT.
Jian Le, Hao Zhang, Chao Gao, Qian Zhou
openaire   +4 more sources

Design optimisation for distance between additional and tap winding in high-voltage transformers

open access: yesHigh Voltage, 2020
The transformer is one of the main components in the power network and transformer windings are one of the most expensive elements in the power transformer.
Kamran Dawood   +3 more
doaj   +1 more source

Potential Early Risk Biomarkers for Reduced Forced Expiratory Volume in Children Post‐Hematopoietic Cell Transplantation

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT We sought to identify potential early risk biomarkers for lung disease in children post‐allogeneic HCT. Patients with pulmonary function tests 3 months post‐transplant and plasma samples between days 7 and 14 post‐HCT were included. Six of 27 subjects enrolled had reduced forced expiratory volume 1 (FEV1) z scores.
Isabella S. Small   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy