Results 221 to 230 of about 1,336 (261)
Some of the next articles are maybe not open access.

The proposal of a new aggregation time interval for calculating the voltage unbalance factor

Electric Power Systems Research, 2012
Abstract When consulting standards that deal with power quality (PQ), it is possible to detect that there are different aggregation time intervals for quantifying voltage unbalance. The choice of the interval to be employed may cause the results of the voltage unbalance factor (VUF) to differ.
João P.J. de Oliveira   +2 more
openaire   +1 more source

Analysis of the complex voltage unbalance factor behavior resulting from the variation of voltage magnitudes and angles

Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010, 2010
This paper presents the main aspects observed in analyzing Complex Voltage Unbalance Factor (CVUF) behavior resulting from the variation of voltage magnitudes and angles. The goal is to identify possible incoherencies regarding the use of the CVUF, and also to investigate whether this factor is more sensitive to variations in magnitude or angles under ...
A. L Ferreira Filho   +5 more
openaire   +1 more source

Approximate Algorithm for Fast Calculating Voltage Unbalance Factor of Three-Phase Power System

IEEE Transactions on Industrial Informatics, 2014
The method of calculating voltage unbalance factor (VUF) recommended by the IEC61000-4-27 has the disadvantage of requiring square root operation. This paper focuses on the fast and accurate calculation of VUF of three-phase power system. The approximate algorithm for calculating the magnitude of the zero, positive, and negative sequences by simple ...
He Wen 0003   +4 more
openaire   +1 more source

Adjustable speed drives supplied with unbalanced voltages: Study under complex voltage unbalance factor parameter

2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America, 2008
The different unbalance definitions applied to three-phase networks are presented shortly, and the unbalance causes and effects on induction motors and ASD are commented. The behavior of an ASD is analyzed when it is fed by an unbalanced voltage centering the attention on the characteristic and non-characteristic harmonic, rms values, K-derating factor,
C. A. Reineri   +2 more
openaire   +1 more source

Calculation of voltage unbalance factor in power system supplying traction transformers

2014 Power Systems Computation Conference, 2014
The article presents the models of transformers with specially connected windings for supplying catenary systems of high-speed rail. Using the symmetrical components method and equations describing the relationship between voltages and currents on the primary and secondary sides of the transformer one can derive equations describing the value of the ...
openaire   +1 more source

Evaluation of voltage unbalance factor for the performance analysis of induction motor

2015 39th National Systems Conference (NSC), 2015
This paper presents the evaluation of Complex Voltage Unbalance Factor (CVUF) on the performance of Induction motor. The assessment of motor performance in terms of copper losses, core loss, power factor, input power, efficiency, etc. are presented. Results show that the effect of phase angle of CVUF should be taken into account while calculating, core
openaire   +1 more source

Optimal online charging of plug-in electric vehicles considering voltage unbalance factor

2017 IEEE Power & Energy Society General Meeting, 2017
The worldwide application and grid-to-vehicle charging of plug-in electric vehicles (PEVs) are expected to tremendously grow within the next few years. Uncoordinated PEV charging in low voltage (LV) distribution networks can lead to local grid problems such as overloading of transformers and voltage unbalances.
Nasim Jabalameli   +2 more
openaire   +1 more source

Effects of various unbalanced voltages on the operation performance of an induction motor under the same voltage unbalance factor condition

Electric Power Systems Research, 1998
Abstract This paper investigates the effects of different unbalanced voltages with the same voltage unbalance factor (VUF) on the performance of a three-phase induction motor and its feedback influence on the power system. Under eight different voltage unbalance conditions, the performance of a three-phase induction motor was measured through a real ...
null Ching-Yin Lee   +3 more
openaire   +1 more source

Calculation Methods of Voltage Unbalance Factor

2023 24th International Middle East Power System Conference (MEPCON), 2023
Ahmed M. El-Bashbishi   +1 more
openaire   +1 more source

Modeling, control and voltage unbalance compensation in a four-switch rectifier with input power factor correction

4th Annual International Power Electronics, Drive Systems and Technologies Conference, 2013
In this paper, a small signal model is proposed for four-switch rectifier with input power factor correction. The required transfer functions are determined and calculated for a typical rectifier. This model is used to design an appropriate controller with defined characteristic to improve the rectifier performance.
Saeed Ouni   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy