Results 141 to 150 of about 177,672 (171)
Some of the next articles are maybe not open access.
Volumetric Capnography in Critically Ill Neonates and Children
2022Joachim Zobel, Gerfried Zobel
exaly +2 more sources
Volumetric Capnography as a Screening Test for Pulmonary Embolism in the Emergency Department
Chest, 2004To compare the diagnostic performance of volumetric capnography (VCap), which is the plot of the expired CO(2) partial pressure against the expired volume during a single breath, with the PaCO(2) to end-tidal CO(2) (EtCO(2)) gradient, in the case of suspected pulmonary embolism (PE).Single-center, prospective study.Emergency department of a teaching ...
Franck Verschuren +2 more
exaly +3 more sources
Validation of Bohr dead space measured by volumetric capnography
Intensive Care Medicine, 2011Bohr's dead space (VD(Bohr)) is commonly calculated using end-tidal CO(2) instead of the true alveolar partial pressure of CO(2) (PACO(2)). The aim of this work was to validate VD(Bohr) using PACO(2) derived from volumetric capnography (VC) against VD(Bohr) with PACO(2) values obtained from the standard alveolar air formula.Expired gases of seven lung ...
Gerardo, Tusman +4 more
openaire +2 more sources
Different Approaches to the Analysis of Volumetric Capnography
2009Lung mechanics and arterial blood gases are the two most common categories of variables used to assess lung function and to adjust mechanical ventilation. Analyzing the kinetics of carbon dioxide (CO2) is another attractive approach to monitor patients receiving mechanical ventilation.
F. Suarez Sipmann, S.H. Böhm, G. Tusman
openaire +1 more source
Volumetric capnography in distinct phenotypes of COPD patients
4.1 Clinical Physiology, Exercise and Functional Imaging, 2016Background: Computed tomography (CT) allows phenotyping of COPD patients, but its relationship with functional features are unclear. Volumetric capnography (VC) uses the principle of gas washout and analyzes the pattern of CO2 elimination as a function of expired volume.
Monica Corso Pereira +4 more
openaire +1 more source
Time and Volumetric Capnography
2013The applications of time and volumetric capnography continue to grow. This chapter provides a brief history of the measurements and makes the case for both time and volumetric capnography in terms of patient safety and as an important clinical tool in the acute care setting.
openaire +1 more source
Current limitations of volumetric capnography in surfactant-depleted small lungs
Pediatric Critical Care Medicine, 2004To investigate the suitability of volumetric capnography for assessing alveolar gas exchange in very small, surfactant-depleted lungs.Prospective animal trial.Animal laboratory in a university setting.Twenty-one ventilated newborn piglets (age
Hans, Proquitté +4 more
openaire +2 more sources
Volumetric capnography to exclude pulmonary embolism at the emergency room
4.3 Pulmonary Circulation and Pulmonary Vascular Disease, 2015Pulmonary embolism (PE) is a potentially lethal pathology which is hard to exclude without expensive imaging techniques. Recent literature suggests the use of end-tidal PCO2 (PETCO2) as a useful parameter to exclude PE. Analysis of the entire curve of the PCO2 in expired air (volumetric capnography, VCap), contains more information. VCap was performed
Timon Fabius +4 more
openaire +1 more source
Volumetric Capnography for Monitoring Lung Function during Mechanical Ventilation
2006Capnography has become standard of care in monitoring respiratory function during anesthesia [1] and together with pulse oximetry has contributed to a major improvement in safety and reduction in morbidity over the last three decades [2].
F. Suarez-Sipmann +2 more
openaire +1 more source
Volumetric capnography for assessing ventilation inhomogeneity in infants with BPD
European Respiratory Journal, 2013Background: Bronchopulmonary dysplasia (BPD) is characterized by structural lung changes which may affect ventilation distribution. Volumetric capnography (VC) has been used in adults to provide information on ventilation homogeneity and ventilation-over-perfusion status.
Christoph Häcki +7 more
openaire +1 more source

