Results 41 to 50 of about 489 (168)

Multi‐Layer MTDC Protection: Design and Simulation Assessment

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This study proposes a novel multi‐layer protection architecture for multi‐terminal DC systems that separates fault current‐limiting and interruption functions. By combining a thyristor‐based fault current limiter with an active resonance circuit breaker, the scheme significantly reduces peak fault currents and di/dt stress, enabling a more compact ...
Jong‐Geon Lee   +3 more
wiley   +1 more source

Comparative Analysis on Small-Signal Stability of Multi-Infeed VSC HVDC System With Different Reactive Power Control Strategies

open access: yesIEEE Access, 2019
Voltage Source Converter based High Voltage Direct Current (VSC HVDC) technology is used more and more in modern power systems. Consequently, in the ac network, an increasing number of converters are appearing in mutual electrical proximity, thus forming
Goran Grdenic   +2 more
doaj   +1 more source

A Novel Method for Starting of VSC-HVDC System

open access: yesInternational Journal of Recent Technology and Engineering (IJRTE), 2021
The voltage source converters (VSCs) are the circuits, which convert the power from one form to the other. The application of voltage source converter is vital in HVDC systems. The voltage source converter technology is employed for the smooth operation of any HVDC system.
G. Vamsi, P.Kiran Kumar, G Joga Rao
openaire   +1 more source

Stability and Synchronization of MMC‐HVDC Systems Using SRF and Inertia‐Based PLLs

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
This study investigates the influence of synchronous reference frame PLL (SRF‐PLL) and the inertia PLL (IPLL) on the stability of grid‐connected modular multilevel converter high voltage direct current (MMC‐HVDC) systems. The findings highlight intrinsic stability limitations of PLL‐based systems, offering insights toward more stable, PLL‐less ...
Shuai Wang, Robin Preece, Mike Barnes
wiley   +1 more source

Interconnection of VSC-HVDC and LCC-HVDC using DC–DC autotransformer

open access: yesThe Journal of Engineering, 2019
This article investigates the feasibility of interconnecting LCC-HVDC and VSC-HVDC through an un-interrupted DC autotransformer (DC AUTO). The interconnected system aims at taking advantage of two HVDC technologies.
Zhihan Yang   +7 more
doaj   +1 more source

Overview of Frequency-Control Technologies for a VSC-HVDC-Integrated Wind Farm

open access: yesIEEE Access, 2021
In modern power systems, the increasing penetration of renewable energy resources has reduced the overall system inertia. However, the intermittent nature of wind power generation reduces frequency stability, which is a crucial issue.
Chung-Han Lin, Yuan-Kang Wu
doaj   +1 more source

An Overview on VSC-HVDC Power Transmission Systems

open access: yesInternational Journal of Control and Automation, 2016
The Voltage Source Converter based High Voltage Direct Current(VSC-HVDC) is a new generation HVDC technology. Because of the technology of the PWM and the turn- on and turn-off electronic apparatus, VSC-HVDC could make up for the defective of the traditional HVDC. And the development is rapid.
Zhenying Pei   +3 more
openaire   +1 more source

Dual-loop primary frequency regulation controller for VSC-HVDC system [PDF]

open access: yes2017 IEEE Manchester PowerTech, 2017
This paper presents a frequency control mechanism for an AC system through the active and reactive power loops of a VSC-HVDC system. The proposed scheme makes use of the reactive power loop for inertia support by exploiting the voltage-power sensitivity of loads, and active power droop control has been used to provide governor-like support following ...
Shah, Rakibuzzaman   +2 more
openaire   +2 more sources

Multi‐Dimensional Stability Constrained Bi‐Level Topology Optimisation Method for HVDC Systems Embedded in Dense AC Grids

open access: yesIET Generation, Transmission &Distribution, Volume 20, Issue 1, January/December 2026.
1) The typical operational risks and coupling characteristics of the AC/DC hybrid power grid are analyzed in detail. 2) A bi‐Level topology optimization method is designed for HVDC systems embedded in dense AC grids. 3) Considering engineering standards of both security and economy, multi‐dimensional security and stability constraints are incorporated ...
Mingxin Yan   +5 more
wiley   +1 more source

Impact of DC Breaker Systems on Multiterminal VSC-HVDC Stability [PDF]

open access: yesIEEE Transactions on Power Delivery, 2016
The use of VSC-HVDC grids for offshore wind farm integration will require the use of dc breaker systems and they, at present, will require dc reactors to limit the rate of rise of fault current. The introduction of large dc reactors throughout a VSCHVDC system can have significant impact on its stable operation and will require additional control. This
Wang, Wenyuan   +3 more
openaire   +3 more sources

Home - About - Disclaimer - Privacy