Results 51 to 60 of about 489 (168)

A Novel Coordinated Control Strategy for VSG to Enhance Power Tracking Speed Without Degrading Inertia Support Capability

open access: yesIET Power Electronics, Volume 19, Issue 1, January/December 2026.
ABSTRACT The virtual synchronous generator (VSG), as a representative grid‐forming control method, has become a key technology in distributed renewable energy systems. However, there exists an inherent trade‐off between fast power reference tracking and high virtual inertia support in conventional VSG control.
Yubin Pang   +3 more
wiley   +1 more source

Coordinated Planning of Flexibility Resources for HVDC‐Connected Renewable Base and Load Center: A CVaR‐Based Probabilistic Approach

open access: yesIET Renewable Power Generation, Volume 20, Issue 1, January/December 2026.
This paper proposes a conditional value‐at‐risk (CVaR)‐based coordinated planning framework to address the volatility and uncertainty in high voltage direct current (HVDC)‐interconnected systems. By jointly optimizing storage deployment, thermal retrofits, and reserve allocation, the method effectively quantifies and mitigates tail risks.
Yu Xiao   +4 more
wiley   +1 more source

Optimization of Wind Power Curtailment by OPF in Hybrid AC/VSC-HVDC Systems With DC Voltage Constraints

open access: yesIEEE Access, 2023
This paper proposes an optimization method for wind power output curtailment based on optimal power flow (OPF) analysis. The wind curtailment ratio is incorporated as a controllable variable in the OPF formulation.
Sangwon Kim
doaj   +1 more source

Accurate Harmonic Voltage Measurement Based on Series Resistive‐Capacitive Divider for Gas‐Insulated Switchgear

open access: yesIET Science, Measurement &Technology, Volume 20, Issue 1, January/December 2026.
A series resistive‐capacitive divider for harmonic voltage measurement of gas‐insulated switchgear was studied. It can step down the voltage while amplifying the proportion of harmonics in the total sensed voltage, thereby increasing the significant figure for the measurement and enabling the accurate measurement of high‐order, low‐amplitude harmonics.
Huizhong Pang   +6 more
wiley   +1 more source

Reactive power sensitivity-based novel overvoltage suppression strategy for parallel VSC-and-LCC-HVDC transmission system

open access: yesInternational Journal of Electrical Power & Energy Systems
The rapid deployment of both line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage source converter-based high-voltage direct current (VSC-HVDC) does not only prolificate AC/DC grid coupling but also form new DC transmission ...
Yi Hao   +4 more
doaj   +1 more source

Power hardware in the loop validation of fault ride through of VSC HVDC connected offshore wind power plants

open access: yesJournal of Modern Power Systems and Clean Energy, 2014
This paper presents the power hardware in the loop (PHIL) validation of a feed forward DC voltage control scheme for the fault ride through (FRT) of voltage source converter (VSC) high voltage DC (HVDC) connected offshore wind power plants (WPPs). In the
Ranjan Sharma   +5 more
doaj   +1 more source

Hardware-in-the-Loop Test Method for Valve Base Controller of VSC-HVDC

open access: yesZhongguo dianli, 2021
The Zhangbei flexible DC power grid project is the world's first voltage source converter based high voltage direct current (VSC-HVDC) project, which brings higher requirements for the reliability of valve base controller (VBC).
Jianliang LU   +6 more
doaj   +1 more source

HVDC Cable System Testing

open access: yesHigh Voltage, Volume 10, Issue 6, Page 1349-1370, December 2025.
ABSTRACT This paper reviews the existing testing techniques for high voltage direct current (HVDC) cable systems, following as a backbone the structure of CIGRE Technical Brochure (TB) 852:2021 ‘Recommendations for testing DC extruded cable systems for power transmission at a rated voltage up to 800 kV’ because it has a fairly similar structure to ...
Giovanni Mazzanti
wiley   +1 more source

Harmonic Analysis of Transmission Scheme for Offshore Wind Farms Based on Diode Rectifier Unit

open access: yesEngineering Reports, Volume 7, Issue 10, October 2025.
This paper builds a general mathematical for the multiple rectifier circuit used in DRU, which is based on the 12‐pulse and 24‐pulse rectifier circuits, and analyzes the harmonics of DRU using different rectifier circuits before and after the installation of AC filters by an offshore wind farm integration project. ABSTRACT The diode rectifier unit (DRU)
Qing Chen   +4 more
wiley   +1 more source

Inter-harmonics in multi-terminal VSC-based HVDC systems

open access: yesJournal of Modern Power Systems and Clean Energy, 2016
Multi-terminal voltage sourced converter (VSC)-based high voltage direct current (HVDC) system composes of a number of VSCs connected to an HVDC grid (or dc grid). The dc grid is often configured by cable interconnections between converter stations, thus
Minxiao Han, Phuchuy Nguyen, Wenli Yan
doaj   +1 more source

Home - About - Disclaimer - Privacy