Results 11 to 20 of about 41,925 (203)

Interplay between VSD, pore, and membrane lipids in electromechanical coupling in HCN channels

open access: yesbioRxiv, 2023
Hyperpolarized-activated and Cyclic Nucleotide-gated (HCN) channels are the only members of the voltage-gated ion channel superfamily in mammals that open upon hyperpolarization, conferring them pacemaker properties that are instrumental for rhythmic ...
A. Elbahnsi   +6 more
semanticscholar   +1 more source

Clinical application of improved VSD and VSD in the treatment of SSI after abdominal surgery: A retrospective randomized clinical study

open access: yesMedicine, 2023
By comparing the efficacy and cost of improved vacuum-sealing drainage devices and vacuum-sealing drainage (VSD) devices in the treatment of postoperative abdominal surgical site infection, the clinical applicability and promotion of improved vacuum ...
Tao Huang, Tong Liu, Mei Shang, Gang Han
semanticscholar   +1 more source

A general mechanism of KCNE1 modulation of KCNQ1 channels involving non-canonical VSD-PD coupling

open access: yesCommunications Biology, 2021
Voltage-gated KCNQ1 channels contain four separate voltage-sensing domains (VSDs) and a pore domain (PD). KCNQ1 expressed alone opens when the VSDs are in an intermediate state.
Xiao-An Wu   +3 more
semanticscholar   +1 more source

Fallot type of absent pulmonary valve syndrome - A case report

open access: yesIndian Journal of Radiology and Imaging, 2020
Absent pulmonary valve syndrome (APVS) is a rare congenital cardiac malformation characterized by absent, dysplastic, or rudimentary pulmonary valve leaflets in association with other cardiac anomalies.
Divya B Desai   +2 more
doaj   +1 more source

Efficacy and Safety of Transcatheter Ventricular Septal Defect Closure Using Nit-Occlud Le VSD coil in Short-term Observation

open access: yesJournal of Agromedicine and Medical Sciences (AMS), 2021
Nit-Occlud Le VSD coil, an alternative device for closing VSD transcatheter, started to be used in dr. Soetomo Hosptal in 2017, but no research has been done on the results of closure with this device.
Saraswati Dewi   +3 more
doaj   +1 more source

Sistem Monitoring dan Kontrol Motor AC Berbasis SCADA

open access: yesJurnal Teknik Elektro Indonesia, 2020
The SCADA-based AC motor monitoring and control system is a three-phase induction motor monitoring and control system. Motor speed regulation feedback is obtained from the tacho generator which is connected to the pulleys.
Ta'ali Ta'ali, Fivia Eliza
doaj   +1 more source

Comparison of customized vacuum sealing drainage and vacuum sealing drainage in the treatment of diabetic foot ulcers: a retrospective analysis

open access: yesJournal of Orthopaedic Surgery and Research, 2023
Background The prevalence of diabetic foot ulcers, a common, more serious chronic diabetes-related complication, is increasing. Vacuum sealing drainage (VSD) constitutes an effective adjunctive treatment for diabetic foot ulcers.
Qingling Chen   +4 more
doaj   +1 more source

Transcatheter closure of a perimembranous ventricular septal defect with Nit-Occlud Lê VSD Coil: A French multicentre study.

open access: yesArchives of Cardiovascular Diseases, 2020
BACKGROUND Transcatheter perimembranous ventricular septal defect (pmVSD) closure remains challenging and is seldom used in France given the risk of atrioventricular block (AVB).
A. Houeijeh   +17 more
semanticscholar   +1 more source

LLaVA-VSD: Large Language-and-Vision Assistant for Visual Spatial Description [PDF]

open access: yesACM Multimedia
Visual Spatial Description (VSD) aims to generate texts that describe the spatial relationships between objects within images. Traditional visual spatial relationship classification (VSRC) methods typically output the spatial relationship between two ...
Yizhang Jin   +9 more
semanticscholar   +1 more source

How should preoperative examinations be chosen for infants with a ventricular septal defect: transthoracic echocardiography, cardiac CTA, or a combination of these two technologies?

open access: yesBMC Cardiovascular Disorders, 2023
Objective To evaluate the accuracy of transthoracic echocardiography (TTE) and cardiac computed tomography angiography (CTA) in detecting the size and location of ventricular septal defects (VSD) in infants.
Wei-Hua Lin   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy